Robust Single Diaphragm Design

Features

•  Flexible installation
•  Compact and simple design
•  12 volt
•  Dry running capability
•  Connections for 3/4" (19mm) ports and 1.0" (25.4mm) ID hose
•  Up to 4.0 US GPM (15 LPM) flow

Specifications

•  Suction Lift: 9.5ft (3m)
•  3/4" (19mm) 90° thru-hull fitting included
•  Control Panel Switch included
•  Relevant Standards:

•  ISO 8846 MARINE Ignition Protection
•  ISO 8849
•  ISO 15083
•  ISO 10133

Performance Rating 

Flow @ 12Vdc Nominal Voltage

Hose Size

Max Lift 

H

2

0

Max Head 

H

2

0ft (0m) Head

3ft (1m) Head

6ft (2m) Head

3.5 GPM (13 LPM) 4.0 GPM (15 LPM) 3.4 GPM (13 LPM) 3/4" (19mm) 9.5ft (3m)

23ft (7m)

Installation

•  The Rule Bilge Pump is self priming up to 9.5ft (3m).
•  Install the Rule Bilge pump in a clean, dry location. (This is not a 

submersible pump.) 

•  Uses multi-positional ports for easy mounting of the pump.
•  If mounted vertically, the motor should be above the pump head.
•  Use rubber grommets provided to absorb 

vibration.

•  Use 3/4" (19mm) i.d. spiral reinforced hose 

(with a smooth internal bore), or semi-rigid 
pipework systems.

•  Connect the hose to inlet and outlet of 

pump using stainless steel hose clamps.

•  All suction connections must be airtight and 

free of sharp bends or restrictions.

•  Inlet hose should run to the deepest point  

of the bilge area.

•  Inlet hose should be cut at an angle in the 

bilge and be secured on a bulkhead or 
stringer with stainless steel clamps to pick 
up all of the bilge water.

•  Run the discharge hose from the pump to 

the 90° thru-hull.

•  Install the thru-hull with a water tight sealant 

and above the water line of the vessel.

•  Use a 7/8" (22mm) hole saw to cut the hole 

for the 90° thru-hull.

•  Secure all plumbing hoses to a bulkhead or 

stringer.

WARNING: 

All marine pumps discharging overboard must be installed  

with the overboard discharge well above static and heeled waterlines.

WARNING: 

Do not use any Rule pump for petrol, petroleum products or 

any products with a flash point below 98°F (37°C), explosion or death may occur.

HOSE

(3/4" ID)

1/8"

(3mm)

1/8"

(3mm)

Suggest 1/8

"

 (3mm) 

(minimum)

Содержание rule DB412

Страница 1: ...DRY BILGE PUMP WITH PANEL SWITCH DB412 INSTRUCTION MANUAL...

Страница 2: ...ine fuel source as described in ABYC E 11 5 3 3 Exception 1 Boats using diesel fuel as the only fuel source 2 Outboard engines mounted externally or in compartments open to the atmosphere in accordanc...

Страница 3: ...ded to absorb vibration Use 3 4 19mm i d spiral reinforced hose with a smooth internal bore or semi rigid pipework systems Connect the hose to inlet and outlet of pump using stainless steel hose clamp...

Страница 4: ...charge piping longer runs reduce flow The number or radius of bends Excess amount of debris in water A strainer or other means of preventing debris from entering the pump inlet should be used to prolo...

Страница 5: ...s recommended that you remove the check valve and drain any residual water from the plumbing Periodically remove clean and inspect bilge pump check valve and its surroundings for damage or debris that...

Страница 6: ...ten until firmly secure Maintenance Check all electrical connections periodically particularly in salt water areas Corrosion can cause loss of performance or non operation in extreme cases The motor s...

Страница 7: ...mbly 13 Shower Drain Bilge Pump Chamber 17 Washer Bilge Pump Service Kit 7 Cover 1 8 Diaphragm 1 10 Hex Head Screw 4 12 Screw Recessed Pan Head 1 14 Shower Drain Bilge Pump Joker Valve 2 15 Shower Dra...

Страница 8: ...onditions of sale copies of which will be furnished upon request 2020 Xylem All rights reserved Rule is a trademark of Xylem or one of its subsidiaries 950 0548 Rev B 05 2020 USA 100 Cummings Center S...

Отзывы: