background image

INSTRUCTION MANUAL

IM354_REV 1 PRINTED IN CHINA

Sump and Effluent Pump

Содержание LSP0712F

Страница 1: ...INSTRUCTION MANUAL IM354_REV 1 PRINTED IN CHINA Sump and Effluent Pump...

Страница 2: ......

Страница 3: ...xamine the unit 5 3 Product Description 6 3 1 General description 6 4 Installation 7 4 1 Preinstallation 7 4 1 1 Pump location guidelines 7 4 1 2 Piping checklist 7 4 2 Typical installation 8 4 3 Wiri...

Страница 4: ...quipment or use of parts not provided by Xylem If there is a question regarding the intended use of the equipment please contact a Xylem representative before proceeding Do not change the service appl...

Страница 5: ...ention to the risks of electric shock or arc flash hazards Always bear in mind the risk of drowning electrical accidents and burn injuries Safety equipment Use safety equipment according to the compan...

Страница 6: ...of solid or liquid waste Clean up of spills Exceptional sites CAUTION Radiation Hazard Do NOT send the product to Xylem if it has been exposed to nuclear radiation unless Xylem has been informed and...

Страница 7: ...at a distributor make a claim directly to the distributor 2 1 2 Examine the unit 1 Remove packing materials from the product Dispose of all packing materials in accordance with local regulations 2 To...

Страница 8: ...an expose you to chemicals including Lead which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov Speci...

Страница 9: ...carry the pump by the power cord Do not remove any tags from pump or cords Do consider a two pump system with an alarm where an installation may become overloaded Do inspect and test system for proper...

Страница 10: ...ording to the local and National Electrical Code Requirements Install a power switch near the pump that disconnects all the conductors Disconnect and lock out electrical power before installing or ser...

Страница 11: ...from the bottom of the sump pit 1 Install a threaded pipe adapter into the threaded pump discharge 2 Install a line check valve just above the union to prevent backflow of water after each pump cycle...

Страница 12: ...of water where the pump turns On and Off The pump should go On well before the water overflows the top of the sump The pump should go Off before the water gets below the pump suction 3 Install a cover...

Страница 13: ...bris and proper switch operation 3 Remove debris which could clog the suction strainer or jam the switch 4 Insure that the switch operates freely and does not hit the sump wall or hang up on piping or...

Страница 14: ...ecommended minimum check the size of the wiring from the main switch on the property If the main switch is up to code contact power company or hydro authority System head too high Purchase different p...

Страница 15: ...eedom of operation and proper installation Incorrect size basin or wet well Adjust system or replace basin with appropriate size Inflow excessive for size of pump Purchase different pump appropriate f...

Страница 16: ...paired or replaced Seller shall have no warranty obligations to Buyer with respect to any product or parts of a product that have been a repaired by third parties other than Seller or without Seller s...

Страница 17: ...in a manner contrary to Seller s instructions for installation operation and maintenance d damaged from ordinary wear and tear corrosion or chemical attack e damaged due to abnormal conditions vibrati...

Страница 18: ......

Страница 19: ......

Страница 20: ...ngs Xylem also provides a leading portfolio of smart metering network technologies and advanced analytics solutions for water electric and gas utilities In more than 150 countries we have strong long...

Отзывы: