![Xylem LOWARA LMR 125-160 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/xylem/lowara-lmr-125-160/lowara-lmr-125-160_installation-operation-and-maintenance-instructions_892227055.webp)
Installation, Operating and Maintenance Instruction
Model LR, LMR, LRZ, LMZ
D
is
c
har
ge t
oo l
ow
D
is
c
har
ge s
tops
af
ter
a t
im
e
H
ead t
oo l
ow
H
ead t
oo hi
gh
D
ri
v
e
me
c
hani
s
m
ov
er
loaded
P
um
p not
r
unni
ng qui
et
ly
T
em
per
at
ur
e i
n pum
p t
oo hi
gh
T
em
per
at
ur
e i
n s
haf
t s
eal
ing t
oo hi
gh
T
em
per
at
ur
e at
t
he bear
ing t
oo hi
gh
P
um
p l
eak
ing
Leak
age r
at
e at
s
haf
t s
eal
ing t
oo hi
gh
Cause
Solution
■
Back-pressure too high
check facility for pollution, open discharge valve
reduce resistance in discharge pipe (e.g. clean filter if
necessary)
use larger impeller (note available motor power)
■
■
■
Back-pressure too low, discharge too low
throttle discharge valve
■
■
Speed too high
reduce speed
compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check reference
value setting
■
■
Speed too low
increase speed (check available motor power)
compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check reference
value settings
■
■
■
■
Flow too little
increase min. flow (open discharge valve, bypass)
■
Flow too big
reduce flow (throttle discharge valve)
■
■
Impeller diameter too big
use smaller impeller
■
■
Impeller diameter too small
use larger impeller (check available motor power)
■
■
■
■
Pump and/or pipes not completely filled with liquid
fill
vent
■
■
■
Pump or suction/intake pipe blocked
clean
■
■
Air pocket in pipeline
vent
improve course of pipe
■
■
■
■
■
Suction height too big / NPSH of system too small
increase liquid level and admission pressure
reduce resistance in the intake/suction pipe (change course
and rated width, open shut-off valves, clean filters)
■
■
■
Air being sucked in
increase liquid level
check if suction pipe is vacuum-tight
■
■
■
Air being sucked in through shaft sealing
clean sealing pipe
increase sealing pressure
replace shaft sealing
■
■
Direction of rotation is wrong
swap over two phases of power supply (to be done by an
electrician)
■
■
■
■
Inner components suffering from wear
replace worn parts
■
■
■
Density and/or viscosity of liquid handled is too high
seek assistance
■
■
Lines and roughness at shaft
replace parts
■
■
Deposits on mechanical seal
clean
replace mechanical seal if necessary
if necessary provide additional rinsing or quench
■
■
Impeller out of balance
remove blocks/deposits
replace impeller if broken or unevenly worn
check shafts to ensure that they are running true
■
■
■
■
■
Forces in pipeline too high (pump unit under strain)
change (support pipes, use compensators, etc.)
is foundation plate/frame properly cast in place?
■
Electricity supply not right (2-phase running)
check voltage of all phases
check cable connections and fuses
■
Sealing insufficient
tighten screws
replace sealing
■
■
Bearing damaged
replace
■
Relief fittings insufficient
clean relief openings in impeller
replace worn parts (impeller, split rings)
adjust in line with the system pressure/intake pressure given on
ordering
■
System-related vibrations (resonance)
seek assistance
page 51
Содержание LOWARA LMR 125-160
Страница 22: ...Einbau Betriebs und Wartungsanleitung Baureihe LR LMR LRZ LMZ Seite 18 ...
Страница 40: ...Instructions de montage de service et de maintenance Série LR LMR LRZ LMZ Page 36 ...
Страница 57: ...Installation Operating and Maintenance Instruction Model LR LMR LRZ LMZ page 53 ...
Страница 65: ......
Страница 66: ......
Страница 67: ......