background image

Ballast SuperKing
DC Flexible Impeller Pump

Содержание JABSCO Ballast SuperKing

Страница 1: ...Ballast SuperKing DC Flexible Impeller Pump ...

Страница 2: ...e equipment If the recommended safety notices are not strictly observed it can lead to serious or fatal injuries of personnel and or material damage It is not recommended to run SuperKing pump dry Do not run the pump with a closed or restricted discharge line This pump is not a submersible pump Failure to observe the recommended safety procedures can lead to material damage Only qualified Service ...

Страница 3: ...he pump is reversible therefore freshwater or seawater can be transferred from source to ballast and returned from ballast to source To reduce ballast the pump will reverse to pump ballast back over board The same operation is used for ballast transfer between two tanks INSTALLATION PUMP SET UP Verify that all components are present Check the pump unit has not been damaged during transit Ensure in...

Страница 4: ... body to motor screws 21 28 lbf ins 2 4 3 1 Nm ELECTRICAL CONFIGURATION AND INSTALLATION 33710 0107 configured with Deutsch DTP04 2P connector Pin 1 Positive Pin 2 Negative It is the responsibility of the installer to per form the correct installation Make all electrical connections in dry loca tions connections in humid environments should be sealed to prevent corrosion Protect the circuit with a...

Страница 5: ...ensional Drawings inches mm 5 12 130 3 56 90 4 2 56 65 89 22 5 2 80 71 1 8 98 228 1 18 30 3 58 91 1 99 50 6 1 36 34 45 2 PLCS 1 25 31 75 2 PLCS 3 74 95 64 16 3 Deutsch DTP04 2P Pin 1 Positive Pin 2 Negative ...

Страница 6: ...t to ensure self priming The pump can run dry up to 1 minute after running wet for 5 minutes TECHNICAL SPECIFICATIONS The data specified in the above table refers to performance running at the ideal efficiency points on water at 68 F 20 C with battery charged at 12 0Vdc For longer installations fit thicker cables reference ISO 10133 The wire length is the total distance from the battery to the pum...

Страница 7: ...tors and cables are in good condition once a month 1 7 2 5 6 3 4 KITS AND ACCESSORIES 33610 0107 Key Part Number Description Qty 1 9328 0202 Kit End Cover 1 2 End Cover O ring 1 3 91004 0090 Kit Screw 12 24 x 375 SL FIL BR 3 per 3 4 98019 0020 Kit Screw 10 32 x 1 2 SL HX BR 3 per 2 5 6303 0007 P Kit Impeller 1 per 2 6 18753 0384 Kit Lip Seal 1 per 1 7 50070 0040 Impeller Removal Tool 1 6303 0007 P...

Страница 8: ...CLUDED EXCEPT AS OTHERWISE PROVIDED BY LAW BUYER S EXCLUSIVE REMEDY AND SELLER S AGGREGATE LIABILITY FOR BREACH OFANYOFTHE FOREGOINGWARRANTIESARE LIMITEDTO REPAIRING OR REPLACINGTHE PRODUCTAND SHALLINALLCASES BE LIMITEDTOTHEAMOUNTPAID BYTHE BUYER HEREUNDER IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES WHETHER DIRECT INDIRECT LIQUIDATED INCIDENTAL CONSEQUENTIAL PUNITIVE EXEMPLARYOR SPE...

Отзывы: