+RZWRSUHYHQWDVLSKRQLQWKH
LQOHWSLSH

This product is designed solely for use 
with Jabsco Vented Loop.  Do not over-
tighten cap as this may damage the 
valve and cause a leak.

Do NOT fit a vented loop into the inlet pipework of 
a pump, where it will admit air (as it is designed to) 
and impede or prevent priming.

Trouble-shooting tip: if the anti-siphon loop makes 
a hissing noise when the pump is running, and the 
clean water flush pump won't prime, the vented 
loop has been fitted in the pump's suction line 
instead of its discharge line.

Remedy: 

In a manual toilet system, remove the vented loop 
from the inlet line and fit it in the discharge line 
between pump and toilet bowl.

In an electric system, where the inlet line requires 
a vented loop, a solenoid valve must also be 
fitted.  

/LWH)OXVKDQG6HULHV
(OHFWULF7RLOHWV

In the Lite Flush and the 37010 series electric 
toilet installations where the clean water inlet line 
has to be protected by an anti-siphon loop, the 
vent in the top of the loop needs to be kept closed 
under suction, so that the pump can prime and 
run.  

Fit an electrically operated solenoid air valve 
(37068-2000) in the top of the vented loop. The 
solenoid will close the air valve only when the 
pump is running, allowing the valve to perform its 
normal siphon-breaking function at other times. 

Continued on page 4... 

X

SEAWATER OR RIVER 

WATER INLET to 

MANUAL TOILET

AT LEAST 
200mm (8") 
ABOVE STATIC 
AND HEELED 
WATERLINES

VENTED LOOP 
FITTED IN PIPE 
BETWEEN PUMP AND 
TOILET BOWL

MANUAL PUMP 
ON TOILET

MANUAL PUMP 
ON TOILET

INLET 
SEACOCK

INLET 
SEACOCK

HEELED

WATERLINE

STATIC

DO NOT FIT VENTED LOOP 
IN SUCTION PIPE BETWEEN 
SEACOCK AND PUMP

29015-0000
Vented Loop
19mm (¾")

37068-2000
Solenoid Air Valve