![Xylem HYDROVAR Watercooled Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/xylem/hydrovar-watercooled/hydrovar-watercooled_installation-and-operating-instructions-manual_3861460020.webp)
20
Over current /
Short circuit
Output current to te motor
is too high due to too high
nominal power of the
motor or short circuit of 2
phases of the motor or the
motor cable.
Check the power consumption of the
motor and the working point of the pump
if they do not exceed the max. output
power of the
Hydrovar
-
Watercooled
nominal power -
Reduce the flow rate.
Check the connection to the motor.
Failure code 46
Overload
Output current is too high
Pump is blocked or tight due to solid
parts inside the pump
Failure code 56
Over voltage
Supply voltage is too high
or spikes on the supply
side.
Check the supply voltage level and all
connections -
If there are spikes on the supply line,
use special filters on the input side
After remedy of the failure reason it is necessary to switch on the
Hydrovar
-
Watercooled
.
Please contact your distributor if the same failure occurs more often. Give a detailed description of the error, the
failure code and the serial number of the
Hydrovar
-
Watercooled.
7
Other failures and possible causes
Failure
Possible cause
Solution
Oscillation of the pressure
Wrong pre-charge pressure in the
pressure tank
Adjust pre-charge pressure
according to the required pressure
or the start pressure when active
Wrong parameter setting
Optimize control parameters
(contact customer service)
Dirty or blocked sensor
Clean the internal sensor piping
and connection
(contact customer service)
Pump does not stop
Wrong pre-charge pressure in the
pressure tank
Adjust pre-charge pressure
according to the required pressure
or the start pressure when active
Check valve is leaky or mechanically
blocked
Clean or change the check valve
Wrong parameter setting
Increase the control window setting
(contact customer service)
Air in the suction pipe or in the pump
Check the suction pipe, and
ventilate the whole system
Flexible or too long suction line
Larger pressure tank necessary
8
Maintenance and Notes
The
HYDROVAR
-
Watercooled
does not require any special maintenance!
For further information, please contact your distributor!
1
2
3
4
5
6
1
2
3
4
5
6