Temperature characteristics of e-SVI 1, 3, 5, 10,
15, 22 (G or N materials)
Standard version for temperatures ranging from
-22°F to 194°F (-30°C to +90°C)
Minimum nominal flow rate
To prevent overheating of the internal pump components, make sure that a minimum water
flow is always guaranteed when the pump is running. If this cannot be achieved, then a
bypass/ recirculate line is recommended.
WARNING:
Do not run the pump against a closed discharge for longer than a few seconds.
For continuous operation the minimum flow rate recommended is specified in the following
table.
Pump Size
Minimum flow gpm
3500 RPM
1750 RPM
2900 RPM
1450 RPM
1SVI
2
1
2
1
3SVI
3
2
3
2
5SVI
7
4
6
3
10SVI
9
5
8
4
15SVI
18
9
15
7
22SVI
21
11
18
9
Starts per hour
For electric pumps coupled to motors supplied by Goulds Water Technology, the maximum
number of work cycles in one hour are as follows:
Hp
Maximum start per hour*
Minimum runtime between starts
in seconds
0.5
24
120
0.75
24
120
1
15
75
1.5
13
76
2
12
77
3
9
30
5
8
83
7.5
7
88
10
6
92
15
5
100
20
5
110
25
5
115
30
4
120
* For more details, refer to the technical manual.
WARNING:
If you use a different motor from the standard one supplied with the electric-pump, check the