5a
5b
5c
6. Install the motor (6a) and tighten the 4 screws (6b) to the values specified in
on page 34.
6a
6b
7. Reinstall the coupling pin (7a) and install the coupling halves (7b). Tighten the 4 coupling
bolts by hand (7c). Locate the spacer supplied in between the coupling and the cartridge
flange (7d). Continue tightening evenly the coupling bolts and torque them to the values
given in the coupling section (the final space between the two halves should be
approximately equal) (7e). Remove the spacer shim and save for future use (7f). Tighten
the 3 set screws of the ring nut to the values given in
(7g).
7a
7b
6 Maintenance
e-SVI series Instruction Manual
27