WS009850A
2. Put a container under the pump and turn the pump.
Remove the oil plug, OIL IN, to simplify the process.
WS009849A
Fill with oil
The oil must be a medical white oil of paraffin type that fulfills FDA Sec. 172.878 (a)
requirements. The viscosity must be close to VG32. These oil types are suitable:
• Statoil MedicWay 32
™
• BP Enerpar M 004
™
• Shell Ondina 927
™
• Shell Ondina X430
™
1. Replace the O-rings of the oil plugs.
2. Turn the pump so that OIL OUT faces upwards.
3. Refit and tighten the oil plug, OIL OUT.
Tightening torque: 44 Nm (33 ft-lb)
8 Maintenance
Concertor
™
6020 Installation, Operation, and Maintenance Manual
39
Содержание Flygt Concertor 6020
Страница 1: ...Installation Operation and Maintenance Manual Concertor 6020 ...
Страница 2: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......