![Xylem Flygt 2840.180 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/xylem/flygt-2840-180/flygt-2840-180_installation-operation-and-maintenance-manual_3870241021.webp)
3. Check that the impeller rotates in the correct direction.
The correct direction of impeller rotation is clockwise when you look at the pump from
above. When started, the pump will react in the opposite direction to the impeller
rotation.
L2
L1
L2
L3
L3
L1
WS001397A
Figure 3: Start reaction
4. If the impeller rotates in the wrong direction, then do the following:
• If the motor has a 1-phase connection, then contact the local sales and service
representative.
• If the motor has a 3-phase connection, then transpose two phase conductors and
repeat this procedure from step 1.
For 3-phase pumps with external starters or without built-in motor protection, the
phases must be shifted on the output terminal of the starter.
Installation
Flygt 2840.180 Installation, Operation, and Maintenance Manual