Proper horizontal and vertical installation
Improper installation with a sharp
bend
WS001379A
WS001346A
Fasteners
WARNING:
• Only use fasteners of the proper size and material.
• Replace all corroded fasteners.
• Make sure that all fasteners are properly tightened and that there are no missing
fasteners.
Install with S-installation
In the S-installation, the pump is transportable and intended to operate either completely
or partially submerged in the pumped liquid. The pump is equipped with a connection for
hose or pipe.
These requirements and instructions only apply when the installation is made according to
the dimensional drawing.
1. Run the cable so that it has no sharp bends. Make sure that it is not pinched, and
cannot be sucked into the pump inlet.
2. Connect the discharge line.
3. Lower the pump into the sump.
4. Place the pump on the base and make sure it cannot fall over or sink.
Alternatively, the pump can be suspended with a lifting chain just above the sump
bottom. Make sure that the pump cannot rotate at startup or during operation.
5. Connect the motor cable and the starter and monitoring equipment according to the
separate instructions.
Make sure that the impeller rotation is correct. For more information, see
Installation
16
Flygt 2125 Installation, Operation, and Maintenance Manual
Содержание Flygt 2125
Страница 1: ...Flygt 2125 Installation Operation and Maintenance Manual...
Страница 2: ......
Страница 45: ...Figure 7 Version code 320 HT Technical Reference Flygt 2125 Installation Operation and Maintenance Manual 43...
Страница 46: ...Figure 8 Version code 320 MT Technical Reference 44 Flygt 2125 Installation Operation and Maintenance Manual...
Страница 47: ...Figure 9 Version code 051 HT Technical Reference Flygt 2125 Installation Operation and Maintenance Manual 45...
Страница 60: ......
Страница 61: ......