FEATURES

• Self–Priming
• Dry Running
• Soft Noise Absorbing Mounts
• Snap–in Port Fittings
• Built-in Bypass : Less Pulsation
• Reduces need for accumulator tank
• Corrosion Resistant Materials

SPECIFICATIONS

Motor: Permanent Magnet, Ball Bearing

Totally Enclosed. CE Models are
fully suppressed.

Pump: Three chamber diaphragm design

Self-priming up to 9 feet suction lift;
Pump able to run dry without damage

Dimensions English (SI)

*CE fully suppressed models are identified by a prefix “R” and a CE mark on the label.(i.e. R3626144).
Self Declaration Of Conformance (SDOC) is available upon request.

OPERATION

With pump switch off and battery fully charged, fill water tank, open all faucets, then turn pump switch on. Water will
begin to flow. When the water is free of air, turn faucets off. Remember, you are filling the water heater and the toilet
and shower lines. When all valves are shut-off, pump will stop. Should pump fail to stop, turn switch off and see the
trouble shooting guide. 

CAUTION - 

Pump surface will get hot to the touch if operated for extended periods of time

under pressurized conditions.

2.25"

3.12"

4.24"

4.75"

3.18"

9.04"

(80 mm)

(65 mm)

(229 mm)

(80 mm)

(108 mm)

(121 mm)

DIMENSIONAL DRAWING

M

o

d

e

l 3

4

2

6

 /

 3

5

2

6

 /

 3

6

2

6

 S

e

rie

s

Pump

Height            Length             Width              Weight

Series

inches (mm)      inches (mm)        inches (mm)           Lb (Kg)

3X26XXX          4.75 (121)        9.00 (229)         6.00 (152)          3.50 (1.59)

MODEL*

VOLTS

AMP DRAW

@10 psi (0.7 bar)

FLOW 

GPM (LPM)

PRESSURE SWITCH

Max psi (bar)

BYPASS

03526144

12V dc

4.4

2.9 (11)

50 (3.4)

Yes

R3626344

24V dc

2.2

2.9 (11) 

40 (2.8)

Yes

R3426144

12V dc

4.4 

2.9 (11) 

25 (1.7)

Yes

R3426344

24V dc

2.2

2.9 (11)

25 (1.7)

Yes

R3426148

12V dc

3.5

2.0 (8)

25 (1.7)

Yes

R3426348

24V dc

1.7

2.0 (8)

25 (1.7)

Yes

“TRIPLEX DIAPHRAGM”

3426 / 3526 / 3626 SERIES

AUTOMATIC WATER SYSTEM PUMP

Содержание FLOJET 3526 Series

Страница 1: ...turn faucets off Remember you are filling the water heater and the toilet and shower lines When all valves are shut off pump will stop Should pump fail to stop turn switch off and see the trouble shooting guide CAUTION Pump surface will get hot to the touch if operated for extended periods of time under pressurized conditions 2 25 3 12 4 24 4 75 3 18 9 04 80 mm 65 mm 229 mm 80 mm 108 mm 121 mm DIM...

Страница 2: ...supporting weight of pump STEP 5 Install inlet A and discharge B port connectors Firmly push slide clips C forward to lock port connectors in place STEP 6 Install a Flojet strainer in an accessible location for inspection and cleaning between the tank and pump inlet This strainer or equivalent is required for pump warranty to be valid STEP 1 Use 14 gauge stranded wire to 20 12 gauge to 50 from pow...

Страница 3: ... Air leak at pump intake Accumulation of debris inside pump and plumbing Worn pump bearing excessive noise Punctured pump diaphragm pump leaks Defective motor EXPLODED VIEW The above part numbers are packaged with 2 fittings per bag STRAINERS Pump Series Strainer Number Inlet Outlet Screen 3X26XXX 1740012 1 2 Barb Quad Port 40 Mesh 1740002 1 2 Barb 1 2 Barb 40 Mesh 1740004 1 2 M Qest 1 2 M Qest 40...

Страница 4: ...mon household bleach needed to sanitize the tank 1 A Multiply gallons of tank capacity by 0 13 the result is the ounces of bleach needed to sanitize the tank 1 B Multiply Liters of tank capacity by 1 0 the result is the milliliters of bleach needed to sanitize the tank 2 Mix into solution the proper amount of bleach within a container of water 3 Pour the solution water bleach into the tank and fil...