background image

Content

1. General
1.1 Preface ......................................................................................................................................... 1
1.2 Commitment  .............................................................................................................................. 1
1.3 Safety regulation ........................................................................................................................ 1
1.4 Safety instructions ...................................................................................................................... 2

2 Introduction of pump ................................................................................................................... 3
2.1 Configuration and application  ................................................................................................. 3
2.2 Type and technical parameters ................................................................................................. 3
2.3 Nameplate  .................................................................................................................................. 4

3 Shipping, handling and storage  .................................................................................................. 4
3.1 Shipping & handling .................................................................................................................. 4
3.2 Storage ........................................................................................................................................ 5

4 Installation  .................................................................................................................................... 5
4.1 pump installation  ...................................................................................................................... 5
4.2 Coupling installation (part of pump are equipped with coupling)  ....................................... 6
4.3 Piping connection ....................................................................................................................... 7
4.4 Electrics connection  .................................................................................................................. 7

5. Operation ...................................................................................................................................... 7
5.1 Preparation and checklist prior to startup  ............................................................................. 8
5.2 Priming ........................................................................................................................................ 8
5.3 Startup ........................................................................................................................................ 8
5.4 Operation and monitoring ........................................................................................................ 8
5.5 Shutdown .................................................................................................................................... 8
5.6 Dismantling ................................................................................................................................. 9
5.7 Allowed startup numbers .......................................................................................................... 9

6 Service ............................................................................................................................................ 10
7 Maintenance .................................................................................................................................. 10
8 Trouble and troubleshooting ........................................................................................................ 10
9 Assembly diagram ......................................................................................................................... 12
9.1 Vertical single pipeline pump (without coupling)  ................................................................... 12
9.2 Vertical single pipeline pump (with coupling)  ........................................................................ 13
9.3 Vertical double pipeline pump (with mechanical seal)  .......................................................... 14

10 Spare parts and pumps  .............................................................................................................. 15
10.1 Spare parts  ............................................................................................................................... 15
10.2 Spare pumps  ............................................................................................................................ 15

11. Equipment administrator list.................................................................................................... 16

12. Log book  .................................................................................................................................... 17
13 Appendix  ..................................................................................................................................... 18

Содержание Bell & Gossett GLC Series

Страница 1: ...GLC series pipeline pump Installation Manual Please leave the manual to the user Read the instructions carefully before Installation operation and maintenance...

Страница 2: ...onnection 7 4 4 Electrics connection 7 5 Operation 7 5 1 Preparation and checklist prior to startup 8 5 2 Priming 8 5 3 Startup 8 5 4 Operation and monitoring 8 5 5 Shutdown 8 5 6 Dismantling 9 5 7 Al...

Страница 3: ...1...

Страница 4: ...2...

Страница 5: ...e in m Hv liquid saturated vapor pressure unit is m converted to water column height Hs safety margin in m usually 0 5m Such as Pb 1bar pump cavitation margin NPSHr 2m Pipe loss Hf 2m safety margin Hs...

Страница 6: ...ing and 6 Service in this manual for more information on the mechanical seal and potentialrisks3 3 Shipping handling and storage 3 1 Shipping handling Check in time if any part is damaged during the s...

Страница 7: ...han the width around the base of the pump set When installed with vibration isolation the vibration damping platform should be 150mm wider than the water pump vibration isolation base Elevation on top...

Страница 8: ...oning plate 4 Screw 5 Bolt 6 Washer 7 Nut 8 Lifting bolt Installation of the coupling must be very careful so that the pump runs reliably for long periods of time Incorrect coupling installation cause...

Страница 9: ...7...

Страница 10: ...8...

Страница 11: ...9...

Страница 12: ...tention to the noise during normal operation If there is vibration abnormal noise abnormal temperature rise of motor or other fault phenomena are observed stop immediately to find out and eliminate th...

Страница 13: ...11...

Страница 14: ...12 9 1 Vertical single pipeline pump without coupling...

Страница 15: ...upling No Description No Description 1 Impeller nut 8 Motor 2 Impeller 9 Coupling parts 3 Wear ring 10 Electric motor bracket 4 Pump cover 11 Sealing gland 5 Mechanical seal 12 Sliding bearing 6 Flush...

Страница 16: ...escription 1 Impeller nut 7 Sliding bearing 13 Mechanical seal 2 Pump body 8 O ring 14 Mechanical seal retainer 3 Impeller 9 Electric motor bracket 15 Shaft Sealing Ring 4 Wear ring 10 Coupling parts...

Страница 17: ...15...

Страница 18: ...16...

Страница 19: ...17...

Страница 20: ...Mx Mb DN40 450 350 410 730 200 300 400 550 DN50 600 500 550 1000 250 350 450 600 DN65 800 650 700 1250 300 350 500 700 DN80 950 750 850 1500 350 400 550 750 DN100 1250 1000 1150 1950 400 500 650 850...

Страница 21: ...In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of...

Отзывы: