Xylem Bell & Gossett CRS Скачать руководство пользователя страница 14

4. Dispose of the old gasket.
5. Replace the cover head gasket with a new one.
6. Install the housing cover.
7. Tighten the flange bolts.

The bolts must be tightened in increments of 30%, 60%, and 100%:

Connection size, in

(mm)

Body size, in (mm) Bolt size, in (mm)

Number of bolts

Torque, lbf.ft (Nm)
150# flanges
Dry

Torque, lbf.ft (Nm)
150# flanges
Lubricated

2 (50.8)

6.5 (165.1)

3/4 (19)

8

250 (339)

175 (237.2)

2.5 (63.5)

6.5 (165.1)

3/4 (19)

8

250 (339)

175 (237.2)

3 (76.2)

6.5 (165.1)

3/4 (19)

8

250 (339)

175 (237.2)

4 (101.6)

8 (203.2)

3/4 (19)

8

250 (339)

175 (237.2)

5 (127)

10 (254)

7/8 (22.2)

12

400 (542.3)

275 (373)

6 (152.4)

12 (304.8)

7/8 (22.2)

12

400 (542.3)

275 (373)

8 (203.2)

16 (406.4)

1 (25.4)

16

600 (813.4)

425 (576.2)

10 (254)

20 (508)

1.12 (28.5)

20

1000 (1355.8)

700 (950)

12 (304.8)

24 (609.6)

1.25 (31.7)

20

1400 (1898.1)

1000 (1355.8)

8. Close the blowdown valve at the bottom of CRS.
9. Open the isolation valves.

6.4  Clean the magnetic insert

6.4.1  Close the isolation valve

1. Before closing the isolation valves, check the following parameters:

– The system water is allowed to reach a safe handling temperature.
– The separator to reach a zero pressure condition.

2. Close the isolation valves to isolate the CRS from the system.

6.4.2  Remove the magnetic insert

WARNING: STRONG MAGNETIC FIELD
This product may contain strong magnets which can be harmful to pacemaker wearers and

others with medical implants. Those with implanted medical devices must stay back 36 in

(90 cm). Keep tools and other loose metal objects away. The magnets in this product are

strong enough to pull them from your hand or can cause a loss of balance. To avoid

damage, keep magnetic media such as computer discs, credit cards, and tapes away.

Failure to follow these instructions could result in serious personal injury, death, and/or

property damage. 

6  Maintenance

12

CRS Instruction Manual

Содержание Bell & Gossett CRS

Страница 1: ...Instruction Manual 0121 01_1 0 CRS Coalescing Style Air and Sediment Separator...

Страница 2: ......

Страница 3: ...ns 7 4 2 Prerequisites 8 4 3 Install the CRS 8 4 4 Pipe hanging installation 8 4 5 Install the insulation 9 5 Operation 10 5 1 Precautions 10 5 2 Start up of the system 10 5 3 System venting and purgi...

Страница 4: ...e safety requirements and information in the original manufacturer s manuals for any other equipment furnished separately for use in this system 1 2 Safety terminology and symbols About safety message...

Страница 5: ...safety goggles protective gloves and shoes and breathing equipment Make sure that all safety features on the product are functioning and in use at all times when the unit is being operated 1 4 Protect...

Страница 6: ...Dispose of all packing materials in accordance with local regulations 2 To determine whether any parts have been damaged or are missing examine the product 3 If applicable unfasten the product by rem...

Страница 7: ...le high performing neodymium magnets The design and construction of this separator conforms to ASME Section VIII Div 1 This product is intended for hot and chilled water systems WARNING This product c...

Страница 8: ...ainer The magnetite and other ferromagnetic particles are collected by the optional magnetic separator 3 3 Parts 1 2 3 4 WS013376A 1 Skim valve port 2 Air vent optional 3 Connection to system 4 Blowdo...

Страница 9: ...tanks and pressure relief valves Failure to follow these instructions can result in serious personal injury or death or property damage WARNING This product can expose you to chemicals including Lead...

Страница 10: ...vice 4 4 Pipe hanging installation CAUTION Lifting lugs Use unit lifting lugs only to lift unit as shipped from factory Unit must be empty and disconnected from pipe and other restraints Use proper ri...

Страница 11: ...properly applied and sized pressure relief valve must be installed and in good operating order During filling and start up after servicing the system pressure should be closely monitored to ensure th...

Страница 12: ...ult local sales and service representative 5 3 System venting and purging CAUTION Uncontrolled venting of water can occur with automatic air vents if foreign material prevents vent from closing Unwant...

Страница 13: ...ure to follow these instructions could result in personal injury and property damage The coalescing medium must be cleaned periodically 6 3 1 Close the isolation valve 1 Before closing the isolation v...

Страница 14: ...he bottom of CRS 9 Open the isolation valves 6 4 Clean the magnetic insert 6 4 1 Close the isolation valve 1 Before closing the isolation valves check the following parameters The system water is allo...

Страница 15: ...st be 24 0 lbf in 4 0 lbf in 0 2 7 Nm 0 5 Nm 0 6 Open the upstream isolation valves 7 Open the downstream isolation valves 6 5 Service the air bleed ports or drain plugs 1 Remove the required componen...

Страница 16: ...The PTFE tape typically does not require curing to achieve the maximum pressure resistance 6 Maintenance 14 CRS Instruction Manual...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...ies and advanced analytics solutions for water electric and gas utilities In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination...