Страница 3: ...ge 6 2 1 2 Examine the unit 6 2 2 Transportation guidelines 6 2 3 Storage guidelines 6 3 Product Description 8 3 1 3DWS 4DWS Series Simplex control panel 8 3 2 Enclosure Mounting NEMA 4X RATED 8 4 Ins...

Страница 4: ...nuals Equipment cannot operate well without proper care To keep this unit at top efficiency follow the recommended installation and servicing procedures outlined in this manual 1 2 Safety WARNING The...

Страница 5: ...rical hazard Magnetic fields hazard Electrical Hazard CAUTION 1 4 Environmental safety The work area Always keep the station clean to avoid and or discover emissions Waste and emissions regulation Obs...

Страница 6: ...rements see sections dealing specifically with electrical connections Precautions during work Observe these safety precautions when you work with the product or are in connection with the product Neve...

Страница 7: ...ith eyewash or running water for at least 15 minutes Seek medical attention Skin 1 Remove contaminated clothing 2 Wash the skin with soap and water for at least one minute 3 Seek medical attentions if...

Страница 8: ...al injury and or equipment damage Lift equipment only at the specifically identified lifting points Lifting devices such as eyebolts slings and spreaders must be rated selected and used for the entire...

Страница 9: ...xtended storage of VFDs may require special attention prior to start up See manufacturer s IOM for details 2 Transportation and Storage 3DWS 4DWS Single Phase Simplex Control Panel Instruction Manual...

Страница 10: ...ack are provided with the premium enclosures To assemble turn the enclosure upside down on a flat surface place the mounting bracket over the square boss either horizontally or vertically and fasten t...

Страница 11: ...ch circuit protection to be provided by installer 5 Panel circuit breakers are closed 6 Floats are accurately mounted at the correct levels Note Floats shall have free range of motion without touching...

Страница 12: ...2 If the level continues to rise the High float will trigger the high liquid alarm This will illuminate the 360 degree visible beacon and sound an 85 decibel at 10 buzzer 5 2 Remote monitoring dry co...

Страница 13: ...the Power On light is not illuminating on the front panel check the voltage at TS1 1 and TS1 2 with a voltage meter The voltage should read 120VAC If voltage is present check the fuse in the fuse box...

Страница 14: ...b subject to misuse misapplication neglect alteration accident or physical damage c used in a manner contrary to Seller s instructions for installation operation and maintenance d damaged from ordinar...