background image

XVME-240 Manual

October, 1984

2.4 JUMPERS/SWITCHES

The DIO module has 9 jumpers and 2 sets of DIP switches. The jumpers and switches

are defined in Table 2-1.

Table 2-l.. The DIO Jumpers and Switch Definitions

Jumper

J2

,

J3, J4, J5,

J6, J7, J8,

J9, 

and 

Jl0

Switch Block

Sl

S2 (switches l-6)
S2 (switch 7)

S2 (switch 8)

Function

Address Space selection jumper (i.e., Short

I/O Address Space or Standard Address Space).

Interrupt input edge detection option jumpers.

Function

 

Selects VMEbus Interrupt Request Level for

module (11-17).

Selects Module Base Address.
This switch determines whether the module will

respond to only supervisory accesses or to both

supervisory and non-privileged accesses.

This switch works in conjunction with jumper 32

to determine whether the board operates with

address modifiers for Short I/O Address Space

or those for Standard Memory space.

2.4.l Base 

Address Switches

The DIO module is designed to be addressed within either the VMEbus Short I/O or

Standard Memory Space. Since each I/O module connected to the bus must have its

own unique base address, the base addressing scheme for XVME I/O modules has been

designed to be switch (or jumper) selectable. When the DIO module is installed in the

system, it will occupy a 1K byte block of the Short I/O Memory (called the module I/O

Interface Block).

The base address decoding scheme for XYCOM I/O modules is such that the starting

address for each I/O Interface Block resides on a  1K boundary. Thus the module base

address may be set to any one of 64 possible 1K boundaries within the Short I/O

Address space.

The module base address is selected by using the switches labeled 1-6  in DIP switch

bank  S2. Figure 2-2 shows the switch bank S2 and how the individual switches (l-6)

relate to the base address bits.

2-3

Содержание XVME-240

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ...s and functional capabilities of the DIO module Successive chapters will develop the various aspects of module installation and operation in the following progression Chapter One A general description...

Страница 7: ......

Страница 8: ...ort I O Address space I O Interface Block The DIO occupies a IK block of the Short I O Address space called the module I O Interface Block Within this block in standard locations are found the I O reg...

Страница 9: ...el output voltage Io1 48mA Io1 16 mA Iol Low level output current Voh High level output voltage Ioh High level output current Voh 2 4V Ioh 2 OV Slave Data Transfer Options A16 D16 STAT A24 D16 STAT In...

Страница 10: ...l to 50 000 ft 15240m Vibration Operating 5 to 2000 Hz 0 015 inches peak to peak displacement 2 5 g peak max acceleration Non Operating I 5 to 2000 Hz 030 inches peak to peak displacement 5 0 g peak m...

Страница 11: ...employs a Data Transfer Bus Arbiter a Subsystem Clock driver a System Reset driver and a Bus time out module The XYCOM XVME 010 System Resource Module provides a controller subsystem with the compone...

Страница 12: ......

Страница 13: ...rs for Short I O Address Space or those for Standard Memory space 2 4 l Base Address Switches The DIO module is designed to be addressed within either the VMEbus Short I O or Standard Memory Space Sin...

Страница 14: ......

Страница 15: ......

Страница 16: ...itch 8 must be set to open If jumper J2B is installed Switch 8 must be set to closed The Standard I O Architecture recommends that the DIO operate within the Short I O Address Space in order to take a...

Страница 17: ...ed Open Privilege Mode Selected Supervisory or Non Privileged Supervisory Only 2 4 4 Address Modifier Reference The following table Table 2 5 indicates the actual VMEbus Address Modifier code that the...

Страница 18: ...nable the IACKIN IACKOUT daisy chain CAUTION The jumper shorting IACKIN to IACKOUT for the DIO s slot in the backplane must be removed or the DIO may be damaged 2 4 6 Interrupt Level Switches Figure 2...

Страница 19: ...BGxOUT x 0 thru 3 Since these signals are already hardwired on the DIO it is not necessary to insert these VMEbus jumpers on the slot occupied by the DIO 2 4 8 Interrupt Input Edge Detection Option Th...

Страница 20: ...Jl0 If a jumper is set in position A then that interrupt input line will latch the interrupt input on the low to high transition of the signal Likewise if a jumper is set to posi tion B then that int...

Отзывы: