1. Product Overview

Xycom Automation industrial monitors meet the rigorous requirements of the plant floor
with high-resolution flat panel displays in a rugged housing with an optional resistive
membrane touchscreen. The ST1210 flat panel monitor delivers crisp, bright text and
graphics with a low current draw, and it fits into panels that CRTs cannot.

The ST1210 is self-contained, requiring only to be panel mounted in an appropriate
enclosure and connected to 120/240 VAC and VGA source.

Standard ST1210 Features

 

12.1" bright (200 Nit), easy-to-read, high contrast (150:1), color (18 bit/262,144

 

colors) TFT flat panel display with SVGA (800x600) resolution

 

Large viewing area and viewing angles (120° horizontal, 100° vertical)

 

Operator input through an optional integrated high-performance (35 million touch)
touchscreen

 

Front panel controls with onscreen menus (lock switch on rear of units)

 

Long-lasting (50,000 hour) backlight

 

Hinged design for easy backlight field replacement

 

Simple mounting

 

Shallow mounting depth

 

Up to 50 foot cables

 

Optional 19" EIA rackmount adapter plate

 

NEMA 4/12 front panel, when properly mounted

 

UL and cUL recognized, CE marked

 

Units ship with all necessary cables and software

When you remove the ST1210 from its shipping carton, verify that you have the parts
listed below. Save the box and inner wrapping in case you need to reship the unit.

 Standard ST1210 Parts List

 

ST1210 unit.

 

Ten-foot VGA cable.

 

Ten-foot serial cable (touchscreen units only).

 

Documentation and Support Library CD-ROM. In addition to containing this manual,
this CD contains all drivers required by this unit (touchscreen drivers in the case of
ST1210T units).

1-1

Product Features

Parts List

Содержание ST1210

Страница 1: ...ST1210 FLAT PANEL INDUSTRIAL MONITOR FLAT PANEL INDUSTRIA Hardware Guide...

Страница 2: ...ns Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense For European Users W...

Страница 3: ...on 2 1 Environmental Considerations 2 1 System Power 2 1 Excessive Heat 2 1 Electrical Noise 2 2 Line Voltage Variation 2 2 Location and Enclosure 2 2 Panel Installation 2 3 Panel Mounting Dimensions...

Страница 4: ...h an optional integrated high performance 35 million touch touchscreen Front panel controls with onscreen menus lock switch on rear of units Long lasting 50 000 hour backlight Hinged design for easy b...

Страница 5: ...the user will appear in a monospace font Operator interfaces such as the Start menu button and keyboard keys such as Enter appear in a narrow bold typeface Other text such as the word Note is bold to...

Страница 6: ...04 3 00 76 20 10 50 266 70 in mm Front Panel Controls The front panel controls from left to right are Menu Select Increment Decrement Their use is detailed in Chapter 3 Monitor Settings 1 3 Product D...

Страница 7: ...006 peak to peak displacement 1 0 g maximum acceleration 0 015 peak to peak displacement 2 5 g maximum acceleration Altitude Sea level to 10 000 ft 3 000 m Sea level to 40 000 ft 12 000 m Electrical...

Страница 8: ...wing practices Separate the power and ground P E or Protective Earth cable from signal cables at the point of entry to the enclosure To minimize the ground wire length within the enclosure locate the...

Страница 9: ...in the specified line fluctuations and still allow the system to function in its operating margin As long as the incoming voltage is adequate the power supply provides all the logic voltages necessary...

Страница 10: ...a readily accessible disconnect device in the fixed wiring on permanently connected equipment Avoid overloading the supply circuit This monitor should be mounted in and used where NEMA 4 and NEMA 12...

Страница 11: ...he monitor is powered up you can access the onscreen display OSD functions by pressing the menu button After the menu appears select the Auto Setup function following the directions given below The mo...

Страница 12: ...age submenu see below Autosetup Automatically adjusts monitor position image size tuning etc Press Increment or Decrement to select Yes or No Miscellaneous Opens the Miscellaneous submenu see below Sy...

Страница 13: ...range is 800 to 880 Auto phase Set the screen to center Press Increment or Decrement to select Yes or No Miscellaneous Submenu Menu Option Description Load Default Load the default settings stored in...

Страница 14: ...e bench 1 TURN THE MONITOR POWER OFF AND DISCONNECT THE LINE CORD 2 Loosen the four thumbscrews that hold the back of the monitor on 3 Separate the two halves of the monitor If the unit is equipped wi...

Страница 15: ...Reconnect the lamp wires to the inverter These are keyed connectors permitting insertion in only one orientation 9 You may now want to clean the LCD and the inside of the monitor window or touchscreen...

Страница 16: ...oft Diagnostic utility MSD or other diagnostic applications 5 Details of attempts made to rectify the problem s and results 6 The log number assigned from Xycom Automation Technical Support if this is...

Страница 17: ...141284 C Xycom Automation Inc 750 North Maple Drive Saline MI 48176 734 429 4971 Fax 734 429 1010 http www xycom com...

Отзывы: