1341 Embedded Node PC                                                         Appendix B – Technical Specifications 

 

 

DW 02Eh,02Fh 

END Main 

Note: Interrupt level mapping 

0Fh-Dh: not valid 

0Ch: IRQ12 


03h: IRQ3 

02h: not valid 

01h: IRQ1 

00h: no interrupt selected 

 

Содержание 1341

Страница 1: ...2007 XYCOM AUTOMATION L L C Printed in the United States of America 1341 Embedded Node PC...

Страница 2: ...ense For European Users WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures INSTALLAT...

Страница 3: ...7 Wall Mounting 7 PCI CARD INSTALLATION 8 JUMPER SETTINGS 10 JP6 CLEAR CMOS SETUP 10 CHAPTER 3 AWARD BIOS SETUP 11 SYSTEM TEST AND INITIALIZATION 11 CHAPTER 4 DRIVER INSTALLATION 13 Windows 2000 Rein...

Страница 4: ...to their usefulness Standard Features The 1341 comes standard with the following features CPU board equipped with a high performance Intel Celeron M 1 3GHz CPU with 400MHz front system bus and 512KB c...

Страница 5: ...installation Front Side Figure 1 1 Front Side Rear Side Figure 1 2 Rear Side Caution Before any installation or un installation please take precautions to prevent damage to the components due to stati...

Страница 6: ...ves you the steps to get the system up and running without explaining the capabilities and options Warning Remove power from the unit and disconnect the power cord before making any adjustments to the...

Страница 7: ...41 Consider locations of accessories such as AC power outlets and lighting interior lighting and windows for installation and maintenance convenience Prevent condensation by installing a thermostat co...

Страница 8: ...nit in the rack or panel in such a way as to ensure that it does not cause a hazard from uneven mechanical loading Incorporate a readily accessible disconnect device in the fixed wiring on permanently...

Страница 9: ...1341 Embedded Node PC Chapter 2 Installation 6 144810 C Mechanical Dimensions Note All dimensions in mm Figure 2 1 Unit Dimensions...

Страница 10: ...4810 C Mounting Options Wall Mounting The 1341 is suitable for wall mount using the included brackets and hardware Secure the bracket to the unit with the 4 screws as shown below Figure 2 2 Wall Mount...

Страница 11: ...wo screws on the rear panel Step 2 Unfasten the three screws on the front panel Step 3 Unfasten the six screws on the bottom lid Step 4 Remove the screw with your finger Figure 2 3 and get the PCI car...

Страница 12: ...attach the screw Step 6 Unfasten the screws Figure 2 4 and push the bracket to lock the PCI card into position Figure 2 5 Figure 2 4 Figure 2 5 Step 7 Close the bottom lid of the 1341 and fasten six s...

Страница 13: ...oard fails to boot due to improper BIOS settings use this jumper to clear the CMOS data and reset the system BIOS information To do this use the jumper cap to close pins 2 and 3 for a few seconds then...

Страница 14: ...y do not match the program outputs an error message You will then need to run the BIOS setup program to set the configuration information in memory There are three situations in which you will need to...

Страница 15: ...your system supports PnP PCI PC Health Status This menu allows you to set the shutdown temperature for your system Frequency Voltage Control Use this menu to specify your settings for auto detect DIM...

Страница 16: ...ev usb Please refer to the driver install instructions included in the 1341 Readme txt file for detailed installation information Windows 2000 Reinstallation If you need to reinstall the Windows 2000...

Страница 17: ...to the reinstallation of your Windows XP operating system and drivers utilizing the XP CD provided with your Pro face Xycom industrial computer If you want to install a new operating system or reinst...

Страница 18: ...15 144810 C Appendix A I O Information A 1 I O Address Map...

Страница 19: ...1341 Embedded Node PC Appendix A I O Information 16 144810 C A 2 Memory Address Map...

Страница 20: ...1341 Embedded Node PC Appendix A I O Information 17 144810 C A 3 IRQ Mapping Chart A 4 DMA Channel Assignments...

Страница 21: ...lbs 5 63 kg Electrical DC AC 9 30 VDC 4 0 A Max 30 W Nominal 100 240 VAC 50 60 Hz 0 4 A Max 33 W Nominal Mounting Wallmount Agency Approvals UL 60950 1 2003 1st Edition E231775 cUL CSA C22 2 No 60950...

Страница 22: ...15 peak to peak displacement 2 5g maximum acceleration 1 These values are with solid state hard drives and not rotating media drives Appendix C Watchdog Timer C 1 Programming The 1341 utilizes the ITE...

Страница 23: ...y state To ensure the initial state of the key check logic it is necessary to perform four write opera tions to the Special Address port 2EH Two different enter keys are provided to select configurati...

Страница 24: ...cifications WatchDog Timer Configuration Registers Configure Control Index 02h This register is write only Its values are not sticky that is to say a hardware reset will automatically clear the bits a...

Страница 25: ...de PC Appendix B Technical Specifications WatchDog Timer Control Register Index 71h Default 00h WatchDog Timer Configuration Register Index 72h Default 00h WatchDog Timer Time out Value Register Index...

Страница 26: ...10 10 Sec dec al Watch_Dog_Setting Timer setting mov al cl mov cl 73h call Superio_Set_Reg Clear by keyboard or mouse interrupt mov al 0f0h mov cl 71h call Superio_Set_Reg unit is second mov al 0C0H m...

Страница 27: ..._Mode PROC NEAR MOV AX 0202h CALL Write_Configuration_Data RET Exit_Configuration_Mode ENDP Check_Chip PROC NEAR MOV AL 20h CALL Read_Configuration_Data CMP AL 87h JNE Not_Initial MOV AL 21h CALL Read...

Страница 28: ...WORD PTR CS Cfg_Port 06h OUT DX AL RET Write_Configuration_Data ENDP Superio_Set_Reg proc near push ax MOV DX WORD PTR CS Cfg_Port 04h mov al cl out dx al pop ax inc dx out dx al ret Superio_Set_Reg e...

Страница 29: ...1341 Embedded Node PC Appendix B Technical Specifications DW 02Eh 02Fh END Main Note Interrupt level mapping 0Fh Dh not valid 0Ch IRQ12 03h IRQ3 02h not valid 01h IRQ1 00h no interrupt selected...

Страница 30: ...nsions 6 Mounting arm 8 wall 7 Preventive maintenance 14 Product information environmental specifications 20 general 1 mechanical dimensions 6 Product specifications environmental 20 Reverse side of u...

Страница 31: ...m Automation LLC Phone 734 429 4971 Fax 734 429 1010 http www profaceamerica com Customer Support Hotline 734 994 0482 Web support http support profaceamerica com Email support profaceamerica com 1448...

Отзывы: