background image

Function (27) Anti­pass mode: 

(0) shows "O N", (1) show s "OFF". (pre­setting figure is 001) Once set at "ON " 

, the card could only be used for matching single entry and exit. This is to 

prevent double entry by using the sam e card if card has been duplicated. 

ke y in 

# syst em pass word# 

ke y in 

# syst em pass word# 

Key in 27 

Key in 28 

Key in # or

 

Key in # or

 

Key in the # or 

 

Key in the # or 

 

Go in to func tion 2 7. 

Go in to func tion 2 8. 

Q ueuing for an ti­ 
p ass mo de inp ut. 

Queuing for d isplay card 
unmbe r mode input. 

Wro ng inp ut, be ep 
sou nd on contin uously. 

Wro ng inp ut, be ep 
sou nd on contin uously. 

S etting succe ssfull y, 
b eep sound o ccurre d. 

S etting succe ssfull y, 
b eep sound o ccurre d. 

bac k to sy stem functio n sele ction. 

bac k to sy stem functio n sele ction. 

E sc sys tem fu nction selection. 

E sc sys tem fu nction selection. 

SYSTEM FUNCT ION 

SE LEC TION : _ _ 

SYSTEM FUNCT ION 

SE LEC TION : _ _ 

Go into sy stem f unctio n setu p. 

Go into sy stem f unctio n setu p. 

sta tus lig ht on,d isplay 
fun ction s electi on. 

sta tus lig ht on,d isplay 
fun ction s electi on. 

A NTI­PASS M ODE 
(0 /ON,1 /OFF) : 1 

D ISPLAY USE R ID 
(0 /ON,1 /OFF) : 0 

D ISPLAY USE R ID 
(0 /ON,1 /OFF) : 2 

D ISPLAY USE R ID 
(0 /ON,1 /OFF) : 1 

A NTI­PASS M ODE 
(0 /ON,1 /OFF) : 2 

A NTI­PASS M ODE 
(0 /ON,1 /OFF) : 0 

Function (28) D isplay card number mode: 

(0) shows "ON", (1) shows "OFF". (pre­setting figure is 000). Once set at "OFF", 

LCD will not display the card number. 

18

Содержание XD200

Страница 1: ...Model XD200 High Capacity RF PIN Access Control System Model XD200 High Capacity RF PIN Access Control System CCTV Manufactured exclusively for Xvision www x vision co uk...

Страница 2: ...mes 12 Anti duress code 13 Total cards 14 Program version 15 Set time 16 Set date 17 Auto record range 18 Main reader location 19 Door shutting time 20 Alarm mode 21 Anti duress alarm mode 22 Door sen...

Страница 3: ...time range Directly link to series type printer for direct data printing Additional sub reader for in out control Equipped with hardware self testing function Internal batteries will provide power sup...

Страница 4: ...cator operation error or unregistered card indicator system starts and setup mode indicator 12345678 4 SC 10 Thin card thickness 0 8 mm ISO standard card dimensions It can be printed directly from car...

Страница 5: ...statuses occurred Mode inquiry Press LCD will display MD ADR YYYY MM DD 2 001 1999 01 01 MD ADR YYYY MM DD open door mode 2 shows door open by proximity card sensing 3 shows door open by proximity car...

Страница 6: ...Release anti duress alarm key in confirmed then press 8 digit card number 8 digit card number 13 00 15 2000 01 01 6 FUNCTION 01 Add new card Either key in 8 digit card number or use proximity card to...

Страница 7: ...ep sound occurred NO such card beep sound on continuously NO such card beep sound on continuously back to system function selection back to system function selection Esc system function selection Esc...

Страница 8: ...dentification mode input Queuing the alarm input is reset or not Wrong input beep sound on continuously Setting successfully alarm is released Setting successfully beep sound occurred back to system f...

Страница 9: ...NEW SYSTEM PASSWORD _ _ _ _ CONFIRM SYSTEM PASSWORD _ _ _ _ CONFIRM SYSTEM PASSWORD 0000 CONFIRM SYSTEM PASSWORD 1234 INPUT NEW SYSTEM PASSWORD 1234 INPUT NEW SYSTEM PASSWORD _ 12 Beep sound on consec...

Страница 10: ...red Setting successfully beep sound occurred back to system function selection back to system function selection Esc system function selection Esc system function selection SYSTEM FUNCTION SELECTION _...

Страница 11: ...back to system function selection Esc system function selection Esc system function selection Esc system function selection SYSTEM FUNCTION SELECTION _ _ SYSTEM FUNCTION SELECTION _ _ SYSTEM FUNCTION...

Страница 12: ...y beep sound occurred Setting successfully beep sound occurred back to system function selection back to system function selection Esc system function selection Esc system function selection SYSTEM FU...

Страница 13: ...range input Queuing for main reader location input Wrong input beep sound on continuously Wrong input beep sound on continuously Setting successfully beep sound occurred Setting successfully beep sou...

Страница 14: ...beep sound occurred Setting successfully beep sound occurred back to system function selection back to system function selection Esc system function selection Esc system function selection SYSTEM FUNC...

Страница 15: ...ly beep sound occurred back to system function selection back to system function selection Esc system function selection Esc system function selection SYSTEM FUNCTION SELECTION _ _ SYSTEM FUNCTION SEL...

Страница 16: ...essfully beep sound occurred back to system function selection back to system function selection Esc system function selection Esc system function selection SYSTEM FUNCTION SELECTION _ _ SYSTEM FUNCTI...

Страница 17: ...d occurred Setting successfully beep sound occurred back to system function selection back to system function selection Esc system function selection Esc system function selection SYSTEM FUNCTION SELE...

Страница 18: ...nuously Setting successfully beep sound occurred Setting successfully beep sound occurred back to system function selection back to system function selection Esc system function selection Esc system f...

Страница 19: ...k to system function selection Esc system function selection Esc system function selection SYSTEM FUNCTION SELECTION _ _ SYSTEM FUNCTION SELECTION _ _ Key in the Press other key Go into system functio...

Страница 20: ...N CONNECTOR 5 PIN CONNECTOR 8 PIN CONNECTOR 6 PIN CONNECTOR Push button switch Diode s white color terminal Nude type electrical lock RS 232 RS 485 Switch RS 232 RS 485 8 PIN CONNECTOR Note 1 Door ope...

Страница 21: ...2V N C Output Note User must ensure the polarity Diode of the wiring connection for additional electric lock is arranged correctly so that it is functional 3 Wiring connection for additional magnetic...

Страница 22: ...er must ensure the polarity Diode of the wiring connection for additional alarm is arranged correctly so that it is functional User must also ensure that Setting Mode 20 Alarm Mode is set ON 8 PIN CON...

Страница 23: ...OR R BK BR O Y G BL P R BK BR O Y G BL P R BK BR O Y G BL P POWERTXDRXD AP30 CONVERTER RS 232 to RS 485 RS 232 RS 485 RS 232 RS 485 interface transit connector PC PC RS 232 communication line RS 232 c...

Страница 24: ...ry for saving if power is cut Equipped intermally with RS 485 interface It can be expanded to 255 terminals linking with computer operation simultaneously 1 Confirm the power supply voltage and polarl...

Страница 25: ...t key enter data Please confirm that the power supply wire and the control wire have been arranged to the space at the back of the LCD this is the wiring arrangement area of this unit This is to preve...

Страница 26: ...nel Step 3 Fit the reader on the base panel power supply wire and control wire must first be inserted and the wires must be arranged correctly Step 4 Use enclosed key wrench and screws to mount the re...

Страница 27: ...RB ST 120ERB AP 10 DC 12V R BK BR O Y GR BL P 8Pin ST 680 R BR GR BL P G N D S P 0 D A T A 0 S P 1 D A T A 1 Wiegand input ST 680 5Pin AP 10 DC 12V Reader ST 110ERB ST 120ERB 27 AP 10 DC 12V 1 2 3 4 5...

Страница 28: ...rica 100 ParkAvenue NewYork City NewYork 10017 United States Email usasales x vision co uk Manufactured exclusively for Xvision www x vision co uk TECHNICAL SUPPORT ForTechnical Support for any Xvisio...

Отзывы: