![XVision VIS249DX Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/xvision/vis249dx/vis249dx_instruction-manual_891524003.webp)
•
Xvision IXC1 Digital Signal Processing (DSP) chip which has been
optimised for internal viewing and features Automatic Gain Control,
Auto White Balance, Back Light Compensation, Low Smear, Edge
Enhancement and Zero Colour Rolling
•
Xvision Pixel+ Varifocal 4.0 to 9.0mm lens with 30° to 64° viewing
angle for super sharp images and easy selection of the optimum
viewing angle during installation
•
Designed for internal use and ceiling mounting
1. Select a suitable position on the wall or ceiling to install the camera.
2. Rotate the dome housing counterclockwise to remove it from the
camera housing.
3. Secure the camera in the desired ceiling position with the four fixing
screws (as shown in Figure 1).
Figure 1
Installation
5 DIP Switch Setting
5.1 Flickerless Function- Set switch -OFF/FL to Flicker to enable
flickerless function. In this mode the switch AES/OFF is auto
disabled. Turning On this function will show you an
alternative colour balance under some lighting conditions.
5.2 AGC-Hi/AGC-Lo Function- Adjusting the switch to AGC indicates
AGC-Hi and in the OFF position indicates AGC-Low. In AGC-Hi
mode, the maximum AGC gain is approximately 26dB. In AGC-Lo
mode, the maximum AGC gain is approximately 16dB.
5.3 Auto Iris Function- The switch AES/OFF should be in the OFF
position to disable the AES function. Adjust the LEVEL with the VR
to the proper level.
5.4 BLC Function- Set switch OFF/BLC to BLC position to enable
Back Light Compensation (BLC) function
F.L.: Flickerless On/OFF
AGC: Auto Gain Control High/Low
AES: Auto Electronic Shutter
BLC: Back Light Compensation
VR Adjustment Level for DC Drive Lens
Inside Control Board
(Colour Normal Resolution)
6
3