Xtricity 4-80053 Скачать руководство пользователя страница 2

WARNING : Risk of fire. Do not aim the bulbs at a combustible surface  
within 3 ft. (1m)

ATTENTION: Keep  the  sensor  at  least  2”  (51 mm) away from the lamps.

1.  MOUNTING AND WIRING THE LIGHT

Note: Do not mount on the ground, recommended installation height is  6 ½ feet to 10 feet

 

** Before you begin make sure that your power is turned off at your circuit breaker box **

1. Install the cross bar (E) to the junction box and secure with the (2) mounting screws (I). 
2. On the cross bar locate GND, attach the ground wire (G) with the grounding Screw (F) 

 

to the cross bar.

3. Use a wire nut (H) to connect the ground wire (G) to the house ground wire (typically copper).  

 

For proper connection, place wire nut over wires and twist clockwise until tight.

4. Connect supply wires with wire nuts (H) as shown in the figure above.
  • Black supply wire connects to the Black power supply wire (Live) 
  • White product wire connects to the White supply wire (Neutral)
5. You may use the optional gasket (D) at this time.
6. Install the light fixture (A) to the cross bar (E).  Use silicon sealant (not included) around the perimeter 

 

of the light to seal for moisture.

7. Screw in the stainless steel screw (C) to hold fixture in place.  

 

Insert plastic screw cover (B) into screw hole.

8. Turn on your electricity after the install has been completed.
9. Turn on power switch.  (If power switch is not on, the light will not cycle on or off)

2.  ADJUSTING YOUR LIGHT HEADS

Your light heads can be adjusted by turning the individual light head to desired position.  You can also adjust your light head 

up and down to your desired position. 

3.  ADJUSTING YOUR MOTION SENSOR

Your sensor head can be adjusted by turning the individual up and down to your detection distance.

INSTALLATION

Note: Mount the fixture higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.

4. SETTING THE MOTION SENSOR

SENSOR ADJUSTMENTS

** You must adjust the motion sensor on the light to the desired area 

 

before you can adjust the time and LUX settings**

TIME SETTING

The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases. 

 

The minimum time (slide switch) is approx. 5 seconds, the maximum time (slide switch) is approximately 12 minutes. 

 

Set the slide switch to control to the desired setting between these limits.

LUX SETTINGS

The LUX slide switch knob control determines the level of darkness required for the unit to start operating.

The setting is best achieved by the procedure below:

•  Set the slide switch knob to the “Night” position on behalf of sensors to work only at night (about : 0-20lux)

•  Set the slide switch knob to the “Dusk”  position on behalf of sensors in the environment into the twilight state 

 

  can work  (about : 0-200lux)

•  Set the slide switch knob to the “Day”  position on behalf of sensors in the environment on behalf of the state can work

 

  during the day  (about :0-2000lux)

SENS  SETTINGS

The SENS slide switch knob control : 

Set the slide switch knob to the “Min”  position. The sensor is low sensitivity setting.

Set the slide switch knob to the “Mid”  position. The sensor is generally sensitivity setting.

Set the slide switch knob to the “Max”  position. The sensor is high sensitivity setting.

Отзывы: