PAGE
7
C. Activating Power-Off Delay Function:
1. While the range hood is on and the blower is running in normal mode, touch
Power-Off Delay
button to activate delay off timer.
2.
Adjust to desired period of delay of timer by touching (-)
or (+)
button quickly (1-15 minutes). Timer begins to countdown immediately, when it
reaches 0, the blower will shut off.
3.
Display screen will show flashing clock if timer is working.
D. Activating Smoke Detector Function:
While the machine is off, touch
Auto Function
button to activate the smoke detector auto function mode.
NOTE: this function will only worked when there’s a lot of smoke. Once this button is touched, all other buttons are not
active.
Note: The smoke detector/ auto function is no longer available on products after 2016.
E. Changing the clock (only available in some models)
While the blower is off:
1. Touch power sign once. The hour indicator will be flashing.
2. Use (+) or (-) to adjust to the desired hour.
3. Touch power sign again for the “minutes”. Indicator will be flashing.
4. Use (+) or (-) to adjust to desired minutes.
5. Touch power sign again to clear the screen. Touch light button to validate. To check time, touch light button.
NOTE: The clock display is only available for product manufactured after October 2013.
F. Remote Control Sensor:
1.
Remote control sensor receives infrared (IR) signal from the remote control. The maximum distance for IR data transmission is 10
feet and requires direct line of sight. The transmission distance may vary depending on temperature and remote control battery
condition.
2. Light settings are independent from other settings (including power-off delay) and lights have to be manually turned on or off.
3.
The system saves user configurations, settings such as light, timer and blower (motor) speed will remain the same the next time it is
turned on.
TYPE 2 (PX04 Models): TOUCH BUTTON
Importance Notice:
4. 2 ½ HOUR AUTOMATIC SHUT OFF: this range hood will be shut off for every approx. 2 ½ hour. You can re-start
operation as usual after it was shut off.
5. 30 HOUR REMINDER: after 30 hours of use, the timer (8) will be flashing. To clear it, please refer to “G-To Clear
Cleaning Reminder” on page 7.
TYPE 2: TOUCH BUTTON
1.
(1) To power ON/OFF, and to activate power-off delay timer.
2.
(2) To decrease blower (motor) speed, decrease timer value, and enter timer mode.
3.
(7) To increase blower (motor) speed, increase timer value, and cumulative timer reset.
4.
(3) Blower (motor) is running light indicator.
5.
(4) Shows current blower (motor) speed (1-4).
6.
(5) Lights up when lights turned on.
7.
(6) To turns ON/OFF lights.
8.
(8) Indicates the accumulated time the system is running.