UPS Management

NetFeeler II (For 3 Ports NetAgent II only)

This page is to set Environmental sensors-NetFeeler II’s configurations.

NetFeeler II 

Critical UnderRun

This section is to set the lowest critical values for temperature and humidity. NetFeeler II

will send a warning message when it detects temperature or humidity values below these settings.

 

Critical OverRun

This section is to set the highest critical values for temperature and humidity. NetFeeler II

will send a warning message when it detects temperature or humidity values above these settings.

Security Label

NetFeeler II may connect up to 7 security sensors. This section is to set the location of searched sensor.

NetFeeler II

Language

This page is to set the language interface for NetAgent.

Interface Language

This section is to set the language for NetAgent web pages. When users first start to open the webpage 

of NetAgent, NetAgent will auto detect the language in the computer system and show the same lan-

guage on its web pages. Users can also choose the languages they prefer from the “Interface Language” 

list.

Note: 

Users will have to enable cookies before they use this function.

Email Preferences

Select language preference when receive emails and SMS.

 

Содержание SNMP-1PIN

Страница 1: ...Web SNMP Cards SNMP 1PMINI SNMP 1PIN SNMP R90 SNMP USB SNMP 3PEX SNMP 2P3 models User Installation Manual www xpcc com 2015 Xtreme Power Conversion Corporation All rights reserved Rev 12 20 18 ...

Страница 2: ...ty 13 UsingNetility 13 UPS Web Management by NetAgent 17 Introduction 17 NetAgent UPS Web Interface 17 Telnet RemoteConfiguration 48 Introduction 48 Telnet Configuration 48 Telnet Configuration 50 ClientMate Windows Shutdown Utility 51 Install ClientMate 51 Using ClientMate 51 SNMPView Windows Based UPS Management System 57 Introduction 57 SystemRequirements 58 Install SNMPView 58 Using SNMPView 5...

Страница 3: ...Xtreme Power Conversion Corporation Web SNMP Cards Page 3 UPS Management Appendix C SMS Server with SMS Modem 81 ...

Страница 4: ...col Providing easy setup and upgrade tools via MS Windows just a few seconds to finish IP setting about 1 5 minutes to upgrade firmware Send SNMP TRAP E mail and SMS for events notification Auto email daily UPS history report Client shutdown software for computer s file saving and graceful shut down SNMP 3PEX Environment Measurement Optional Kits External modem dial in out via PPP protocol or GSM ...

Страница 5: ...down utility is installed the shutdown utility could close all the files and shutdown the system when a abnormal power condition happened 2 When we need to monitor environmental conditions of the machine room warehouse office etc For ex ample the system manager could know the temperature humidity smoke and water condition by using the SNMP 3PEX and SNMP EMP The system manager could continuously mo...

Страница 6: ...al 4 M2501 Cable for Contact Closure UPS 5 M2502 or M2505 Cable for RS232 UPS 6 M2506 Cable for Modem 7 9V DC adapter External SNMP 1PMINI 1 Internal NetAgent Mini 2 NetAgent Utility CD 3 User Manual Internal SNMP R90 1 Internal NetAgent Mini 2 NetAgent Utility CD 3 User Manual 4 5 3V DC adapter External SNMP USB 1 Internal NetAgent Mini with LCD Display 2 NetAgent Utility CD 3 User Manual 4 5 3V ...

Страница 7: ...tdown utility SNMPView Windows platform multiple NetAgent UPS management software SMS Server SMS Notification UPS MIB MIB file for the Network Management System Time Server Time adjustment utility And NetAgent Installation User s Manual M2502 or M2505 Cable For external NetAgent II connection to RS 232 UPS M2506 Cable For connection SNMP 3PEX and Modem 9V DC Adapter For SNMP 3PEX 5 3V DC Adapter F...

Страница 8: ...atus Solid Off Solid Off Solid ON Power ON Flashing Solid ON Solid ON System initial Solid ON Solid Off Solid ON Normal operation Solid ON Flashing Solid ON No connection to UPS Flashing Flashing Solid ON Writing data to flash memory Green light Power state Red light Connection state with UPS SNMP 1PMINI SNMP R90 ...

Страница 9: ...sh memory Green light Power state Red light Connection state with UPS Light signal application Status LED Light color Signal definition Condition description Green Power state On Normal power Red Connection state with UPS Flash no connection with UPS Orange Correspondence state Light flashes when Netagent transmits command to UPS Light signal application LAN Port LED Light color Condition descript...

Страница 10: ...allation connects the NetAgent and UPS and network Software configuration includes the IP address Firmware upgrade Or using the Browser or Telnet for configuration You could also install the shutdown utility ClientMate to protect your Windows operating system And also could use the UPS management software SNMPView to control and manage multiple UPS on the network NetAgent UPS installation flowchar...

Страница 11: ...PS and Network For SNMP 1PMINI Please make sure the connector direction of the cable is correct before connecting to the NetAgent Connect the NetAgent module to LAN using the UTP port SNMP 1PMINI Installation For SNMP 3PEX Connect the NetAgent Adapter to LAN using the appropriate UTP port Connect the specified serial cable M2501 M2502 M2505 from NetAgent Adapter to the serial port of UPS Plug supp...

Страница 12: ...NMP 1PIN Installation For SNMP R90 and SNMP USB Connect the NetAgent to LAN using the UTP port Connect the cable from NetAgent to the serial port of UPS Plug the DC adapter to UPS outlet the DC plug connects with NetAgent SNMP USB Installation Warning Please make sure the input Voltage and Frequency of the DC power adapter NetAgent II DC 9V NetAgent Mini DC 6V or 5 3V is correct before plugging it...

Страница 13: ...f the NetAgent devices found on the LAN the left side is the function selection menu Netility Main Window Launch Device Click Launch Device or double click the NetAgent listed in the table to launch it Enter the Account Login Name and Password Login Password set earlier to login If you did not configure the login yet then just click Apply to login Network Settings Choose the NetAgent from the righ...

Страница 14: ...r the man ager Concerning security the manager could build use openly or any advance port setting methods Followings are the description 1 At advanced setting two functions were set as activated by using port number 80 and 23 for Http and Telnet As for Https and SSH are 443 and 22 2 Unselect means not using the function 3 When set to the other port value full IP Address must be entered in order to...

Страница 15: ...rmware upgrade function When you are going to upgrade firmware click Down load Firmware from the NetAgent Setup menu click Browser select new firmware file bin and press Start NetAgent s Red LED and Yellow LED flashing alternative means the firmware is upgrading After upgrade is com pleted Net Agent will auto reboot To upgrade multiple NetAgents simultaneously with the same firmware hold the Shift...

Страница 16: ...tAgent will keep its default data to avoid complete data loss In this case just repeat firmware upload upgrade Netility Update NetAgent UPS firmware About Netility version examined Netility version examined Refresh List Search Lan s Netagent UPS manually Netility can search for all of the available NetAgent on Lan automatically or the user can search manually by clicking on Search NetAgent ...

Страница 17: ...on Netility e g 192 168 0 156 Input NetAgent UPS IP address On the first screen enter the current password If no password has been set just press ENTER NetAgent UPS Login dialog NetAgent UPS Web Interface Enter NetAgent UPS Web page there are 4 main selections in the first Web page Information Configuration Log Information Help Enter the selection item the sub menu items will be shown on the left ...

Страница 18: ...Xtreme Power Conversion Corporation Web SNMP Cards Page 18 UPS Management NetAgent UPS single port NetAgent UPS 3 ports NetAgent 9 ...

Страница 19: ...nfiguration pages System Information This section is to show NetAgent system information Values in Hardware Version Firmware Version Serial Number System Time are provided by NetAgent itself Other values are user settings from the Configuration pages Network Status This section is to show NetAgent Network settings The MAC address is provided by NetAgent All other values in this section are user se...

Страница 20: ...will be displayed in red when there is a power event Input Status This section is to show the UPS input status including AC Status Input Voltage Input Frequency Values here will be shown in red when an abnormal status condition occurs Output Status This section is to show the UPS output status including Output Voltage Output Status UPS Loading Values here will be shown in red when an abnormal stat...

Страница 21: ... UPS self test Deep Battery Test This function is to initiate XX minute deep battery test Test Until Battery Low When initiated UPS will test Battery until battery low Cancel Test This function is to abort a test when it is in progress Turn off UPS when AC failed Reboot UPS Selecting Turn off UPS when AC failed will turn off the UPS You can reboot the UPS by selecting Re boot UPS Put UPS in Sleep ...

Страница 22: ... UPS load will turn off and then turn back on UPS Buzzer On Off This is to trigger UPS buzzer On If its ON already initiating this command will set it OFF Remote Control Meter Chart This page displays temperature capacity load voltage etc of the UPS by appearing with meters chart diagram Meter Chart ...

Страница 23: ...9 Meter Chart Modem Status For 3 Port NetAgent II only This page displays Modem s status and information when 3 port NetAgent II connects with modem Modem Information This section displays the modem information GSM Modem Operating Status This section displays the operating status between NetAgent and Modem ...

Страница 24: ... detects an abnormal status condition In addition NetFeeler II will also set off an alarm for notification NetFeeler II Status Environmental Temperature This section is to show current temperature which is detected by NetFeeler II Environment Humidity This section is to show current humidity which is detected by NetFeeler II shown as Water Status This section is to show water presence ie flood whi...

Страница 25: ...ay values or disconnec tion between the UPS and NetAgent UPS Properties UPS Communication Type This section is to set up the communication interface of the UPS eg Contact Closure Megatec Phoenix tec Megatec 3 phase etc Please refer to the UPS manual to set the correct communication type Any incorrect settings will cause disconnection between the UPS and NetAgent Number of Batteries Battery Full Ch...

Страница 26: ...n is to set a period of time after which NetAgent will send a disconnection warning message This warning message will be sent after NetAgent has lost contact with the UPS for the time specified Critical Loading This section is to set the UPS critical loading shown as NetAgent will send a warning message when the UPS load exceeds this value Critical Temperature C This section is to set the UPS crit...

Страница 27: ...he settings here override the settings in Weekly Schedule Warning will be initiated _ before Schedule shutdown event NetAgent will send a warning message before a scheduled shutdown This section sets the delay time period after the message is sent and before the scheduled shutdown is started Wake On LAN This section is to wake the PC within the network Make sure the PC supports this function and c...

Страница 28: ...king Ethernet Connection Type This section is to set communication speed between NetAgent and Network NetAgent will reboot after Connection Type is changed Stop UPS communication when Ethernet disconnected This section is to set whether or not to stop UPS communication when NetAgent disconnects with Ethernet Dynamic DNS This is a free service that allows the user to alias a dynamic IP address to a...

Страница 29: ... your xDSL modem Once set up NetAgent will connect directly to the Internet without going through a router The LCD will display the current WAN Public IP instead of the LAN IP Address When Connection should be made This is set if using PPPoE to connect with NetAgent UPS Disabled Default setting Connect always NetAgent will automatically dial up and maintain continuous connection Login Name Enter t...

Страница 30: ... section is to set a Community name for NMS The community name has to be the same as the set ting in NMS Permission This section is to set authorities of administrators Options are Read Read Write and No Access Username password When using SNMPv3 username password must be entered Password must be at least 8 characters Sender and Recipient s password must match to communicate Authentication This is...

Страница 31: ... To receive only severe traps Please refer to NMS manual for Trap levels Accept This section is set to select whether to recieve a trap or ot Description This section is for an administrator to make notes Event This section is to select events for NetAgent to send traps Clicking on Select will open a Select Events List Or Click on Test to send test trap Event Traps may be selected from this list E...

Страница 32: ...section is to set the power usage and connection status of other devices powered by the same UPS as the NetAgent is connected to SNMP UDP This is to configure the UDP port of the NetAgent and trap receiver SNMP default port is 161 and Trap MIB is UDP162 SNMP NetAgent 9 SNMP Email ...

Страница 33: ... address configured Recipient s Email Address for Event Log This section is to set Email Addresses to receive warning email sent by NetAgent when an event occurs It is valid for up to 8 Email addresses Send Email When Event Occurs This section is to set NetAgent to send warning Email when an event occurs Account 1 8 8 email addresses could be configure with selected event Event This section is to ...

Страница 34: ... single and three ports of NetAgent To send SMS by single port of NetAgent it requires to use remote SMSAgent or freeware SMS Server SMS Settings Send SMS when Event Occurs This section is to select if use local modem or remote service to send SMS Select local modem when mo dem connects with 3 Ports NetAgent Select remote service if modem connects to PC using SMS Server software or connects with S...

Страница 35: ...ellular number for Event Log This section is to set the recipient s mobile number A total of 8 mobile numbers can be assign Select able events list is same as SNMP webpage Refer to page 35 figure 31 UPS Event Note 1 Enter mobile number same as sending from mobile Note 2 Please refer to SMSAgent s user manual for further information Note 3 See Appendix for further information SMS NetAgent 9 SMS Mod...

Страница 36: ... make sure the local telecom supports such service CDMA To use with GSM 800 900 1800 frequency and make sure the local telecom supports such service SIM Card PIN Enter the SIM password Confirm SIM Card PIN SIM Password must match the one set above Receiver cellular number and message content To send instant SMS enter recipient s mobile number and SMS text with configurable of Unicode or Character ...

Страница 37: ...set user s authorizations of Read or Read Write IP Filter This section is to set a particular IP address Users can only gain access to NetAgent web pages if they come from this IP address If you want to manage NetAgent from any IP address you can set it as RADIUS Server Settings This is to configure the parameter of the radius server Please refer to the appropriate radius server set ting Only for ...

Страница 38: ...ormation This is to upload the SSL public key Only for NetAgent BT CT DT series and NetAgent 9 series of BX CX DX models SSL Certificate Information This is to upload the SSL certificate When both public key and certificate are uploaded to NetAgent web server the communication will be encrypted by SSL on the Internet by entering with Http on the browser To communicate via Https make sure to enable...

Страница 39: ...ization Time Server Choose the nearest Time Server to your NetAgent location The Administrator can choose from the list of a maximum of 30 Time Servers If to add new time server click on Edit and delete any time server from the list provided and add a new one Time Zone Relative to GMT This section is to set a different time zone for different countries Using Daylight Saving Time Choose between Yes...

Страница 40: ...or 166 65 hour or 1 to 9999 Hour 1 hour to 416 6 days Manual Restart System After 30 Seconds Use this feature to manually restart the system NetAgent restart in about 30 seconds Backup Time This is to save the event log and data log automatically with the configured hour on external USB flash This only applies on BX NetAgent models and the USB flash disk must be with FAT FAT32 format Time Between ...

Страница 41: ... message when it detects temperature or humidity values above these settings Security Label NetFeeler II may connect up to 7 security sensors This section is to set the location of searched sensor NetFeeler II Language This page is to set the language interface for NetAgent Interface Language This section is to set the language for NetAgent web pages When users first start to open the webpage of N...

Страница 42: ...alian Turkish Russian Polish NetAgent 9 CX DX and BX supports the following languages English Traditional Chinese Simplified Chinese Korean Japanese Russian Thai German Portuguese Spanish French Italian Turkish Russian Polish Log Information Sub Menu Event Log SMS Data Log Save Data Log NetAgent Log Record Log Information Model Single Port DP CP Single Port DT CT CX DX 3Ports BT BX Event Log 100 l...

Страница 43: ...me hh mm ss that the event occurred Event This is a detailed description of the event Save This is to save the event log Event Log SMS This page is a SMS Event log It shows a record of all mobile number giving the Date Time of the SMS sent and a detailed description of each When reach to the limit it rewrites on the previous logs ...

Страница 44: ...S configuration UPS recorded UPS data Log Input Volt This section shows records of the UPS Input voltage readings Unit Volt Output Volt This section shows records of the UPS Output voltage readings Unit Volt Freq Hz This section shows records of the UPS Input Frequency Unit Hertz Load This section shows records of the UPS Output loading shown as Capacity This section shows records of the UPS batte...

Страница 45: ...oration Web SNMP Cards Page 45 UPS Management Date Log Save Data Log This function is to record RS232 UPS s voltage frequency load capacity temperature etc to save as another file for the other purpose to the manager Save Data Log ...

Страница 46: ...l re search all the NetAgent in the network Serial Port Debug This function is to know the immediate communication between NetAgent and UPS via serial port Port Information This is to configure the communication parameter between NetAgent and UPS Parameters are Debug Mode Port Speed Baud Data Bits Parity and Stop Bits Two encoding formats ASCII or Hexadecimal If Debug mode is set as manually user ...

Страница 47: ...ault format of YYYY_ MMDD_ cfg Administrator permission required Restore previous configuration Use this function to restore a cfg configuration that has been saved earlier Click Browse to the loca tion of the file and click Restore Reset to factory default This function will reset all settings to its default value Firmware Update Setting Default FTP server is set as ftp icv99 com with its usernam...

Страница 48: ... tw Download htm NetAgent to download the available firmware About Telnet Remote Configuration Introduction NetAgent supports multiple Network Management systems and LAN protocols After finishing hardware installa tion you are now able to choose any utilities that provided by NetAgent to monitor and control UPS Here are introduction for using Telnet Telnet Configuration Select Start from Windows c...

Страница 49: ...B System This function allows you to set the MIB system group parameters 3 Set SNMP Access Control This function allows you to set the Manager IP Community Access Permission Note The configuration of Set SNMP Access Control is only used for SNMP Network Manager 4 Set SNMP Trap Notification If you want to use a PC and perform the Trap function of SNMP manager to manage UPS through Net Agent the IP ...

Страница 50: ...mail accounts to receive power event notification for emergency management a Reset Configuration to Default Set all values to their default settings b Save Reboot Save the current configuration data including any changes you have made and reboot the Net Agent 0 Exit Without Saving Exit all configuration changes will be lost Telnet Configuration Use Putty software to configure SSH Telnet encryption...

Страница 51: ...indows system on the network When the ClientMate detects the AC Fail Battery Low Schedule Shutdown signals from the NetAgent it will save the file and shutdown the system Please check the operation description here below Install ClientMate Put the NetAgent Utility CD into the CD driver And execute the ClientMate program After complete installation there will be a ClientMate group in the Windows St...

Страница 52: ...nt Config When the ClientMate gets the signal from the NetAgent about the AC power failure or battery low signals the ClientMate will based on the configuration below to initiate the shutdown process The details of the configura tion are here below ClientMate Configuration ...

Страница 53: ...MP port must be the same as configured on NetAgent Default SNMP Port is 161 4 Broadcast Warning Messages On Server platform only To configure if sending the warning messages when power failed only for WinNT Win2000 and XP server operating system 5 Configuration Password To set if password is require to be entered when effect any new setting on ClientMate If lost of pass word just re install the Cl...

Страница 54: ...me before the Schedule Shutdown to make notification 16 Auto save application files Check if to save the application files before system shutdown 17 Run Application before shutdown computer Execute the application before system shutdown ClientMate Configuration Closed Files User could review all the files closed during previous shutdown process If the Auto save application files func tion has been...

Страница 55: ...anagement ClientMate Closed Files About Press this button could review the version information of the ClientMate as here bellowed ClientMate About Event log Press this button could review all the network status and UPS status happened Shown as below ClientMate About ...

Страница 56: ... with NetAgent UPS at IP 192 168 0 162 Does not connect to any NetAgent AC power status Status ICON Description The connected NetAgent UPS AC power is normal The connected NetAgent UPS AC power is failed AC power status Status ICON Description The connected NetAgent UPS AC power is normal The connected NetAgent UPS AC power is failed ...

Страница 57: ...nform the designated network manager It can also inform the user of the UPS current condition or configuration perform self test send a history file turn the UPS On Off and more SNMPView features A windows interface that is simple and user friendly Automatic detection and identification of any UPS with NetAgent II or NetAgent Mini connected to a net work Capable of simultaneously monitoring up to ...

Страница 58: ...n there will be a NetAgent group in the Windows Start group Click NetAgent Æ SNMPView Æ SNMPView for Windows to start using SNMPView Using SNMPView When use SNMP view at the first time the system will ask for input the user s name and password Please enter the default value as follows to start the SNMPView User Name Admin Password blank just press Enter After the SNMPView program start up the main...

Страница 59: ...w functions list Followings are the explanation of each function icon Enumerate Search all SNMP hosts that supports Public group and display them on the screen Add UPS Manually add a host into the window Delete UPS Manually delete a host into the window Group Shows the Main group windows Settings If the host is a UPS just click on it to view and modify the UPS s general information Monitor If the ...

Страница 60: ...arameter for community Trap port and UPS SNMP port Enumerate D Start SNMPView and press the Enumerate button SNMPView will start a search for all the NetAgent on network and list them in the main window Enumerate When press SNMPView will start a search for all the NetAgent on network and list them in the main window Add Group This is to edit or display all the group station of NetAgent under netwo...

Страница 61: ...ly Once entered the UPS will be shown on the main list Delete UPS Highlight the unit to be deleted from main list and right click on it to choose Delete or use click on the Delete icon from main function list Hold On Shift to select multi NetAgent UPS Browse Device Highlight the unit to be browsed and click it to enter NetAgent s webpage ...

Страница 62: ...Conversion Corporation Web SNMP Cards Page 62 UPS Management Export Configuration This is to save the NetAgent UPS s configuration Import Configuration This is to import the configuration of NetAgent UPS that saved ...

Страница 63: ...UPS Management Open archive Event Log Open up SnmpElog dat SNMPView would show the event log of all NetAgent UPS Open up SnmpElog dat event log would show as below Open archive Data Log Open up SnmpDlog dat SNMPView would show the event log of all NetAgent UPS ...

Страница 64: ...eme Power Conversion Corporation Web SNMP Cards Page 64 UPS Management Open up SnmpDlog dat data log would show as below Quit Exit SNMPView View s This is to choose the presentation format of NetAgent UPS ...

Страница 65: ...isplay NetAgent UPS s IP address Name location etc Details Detailed Information displays NetAgent UPS s IP address name input voltage output voltage battery capacity load frequency etc Map Background Import a map image JPG by right click on the main screen and move NetAgent UPS icon to its suitable location ...

Страница 66: ...nable trap alarm etc Email Send email notification when event occurs Sender Display name Please enter sender display name Sender email address Please enter sender email address SMTP server address Enter SMTP address IP address or domain name Server requires authentication Click Setting then enter your Account Name and Account Password Notified Email Address Click add and enter new email address ...

Страница 67: ...Xtreme Power Conversion Corporation Web SNMP Cards Page 67 UPS Management SMS Notification Send SMS when event occurs Trap List Double click on the trap that listed and configure ...

Страница 68: ... its load that connects with NetAgent UPS Double click on the device listed and configure UPS Monitor Highlight NetAgent UPS device and configure Or right click on the highlighted device and click on monitor device Meter Display NetAgent UPS information such as input voltage output voltage temperature capacity etc in diagram ...

Страница 69: ...Cards Page 69 UPS Management Digital Display NetAgent UPS information such as input voltage output voltage temperature capacity etc in digital Details Display NetAgent UPS s IP address location user manufacturer and all other detailed information ...

Страница 70: ... AC Fail Simulate AC failed to UPS UPS Sleep UPS enter sleep mode Once choose the function that to perform and click on Execute Note UPS must supports those function to perform it Test Control UPS Self Test Execute UPS Self Test UPS Calibration Test Execute UPS Calibration Test Turn Off Parameters Turn Off Delay To set the buffering time for UPS before shutdown Sleep Time To set UPS sleep time Tes...

Страница 71: ...Xtreme Power Conversion Corporation Web SNMP Cards Page 71 UPS Management UPS Magaement To configure SNMP of its NetAgent UPS ...

Страница 72: ...MP Cards Page 72 UPS Management System s To view event log data log and configuration Event Log Display event log date time and description of all NetAgent UPS Data Log Display input voltage output voltage frequency load etc of all NetAgent UPS ...

Страница 73: ...nt SNMP Option To set NetAgent UPS s parameter User U Total of 8 users account can be created to manage and control its NetAgent UPS Change Password To change existing user s password to login User Management This only for Admin user to add edit or remote other user s info ...

Страница 74: ...MP Cards Page 74 UPS Management Help H Display the current SNMPView version and operation information HTML Help This to check the operation of SNMPView About Display the current SNMPView version Copyright information and product service contact ...

Страница 75: ...ase follow the instruc tion below to update the firmware If there is other FTP client application on your computer that will also be fine to use it for updating the firmware For example if wish to update the latest firmware of the NetAgent UPS which IP address is 192 168 50 179 then please operate with the steps below Enter Windows then type ftp 192 168 50 179 under Run of the Start Menu After exe...

Страница 76: ...est NetAgent firmware file c work netagent prjs nag 2 32 DK520 bin which is in this computer to the NetAgent UPS with IP address of 192 168 50 179 3 Use IE browser to update suitable for BK CK DK BP CP DP version This method is to enter the account password and IP address of the NetAgent UPS which the user wish to update under the website column Once entered user may see the current firmware versi...

Страница 77: ...ation Web SNMP Cards Page 77 UPS Management Once the connection been established the following window will be display Then the user may transfer the latest firmware to here for the replacement in order to complete the updating steps ...

Страница 78: ... UPS Management Appendix B 3 Ports NetAgent II with SMS Modem BP506 SMS MODEM Hardware Installation A GSM MODEM B GSM MODEM Adaptor C NetAgent BP506 D GSM MODEM Cable E RS232 to RJ45 Cable 1 2 How hardware should be connected 3 Before use GSM MODEM insert SIM ...

Страница 79: ... card has password invalid pass word If such conditions happens please unplug plug the power on Modem and it shall ready SIM again If Led doesn t flash continuously once every 8 seconds then Modem is working properly BP506 Modem Configuration 1 BP506 Modem 2 Modem communication Type Select SMS 3 SMS Communication Select GPRS 4 Enter SIM Card PIN leave blank if none 5 Click on Apply 5 Under Modem s...

Страница 80: ...on Web SNMP Cards Page 80 UPS Management BP506 SMS Configuration BP506 Configuration 1 SMS 2 Select Local Modem 3 Enter BP506 s username and password leave none leave blank 4 Enter Mobile number 5 Select events to send 6 Click on Apply ...

Страница 81: ... C SMS Server with SMS Modem GPRS MODEM Installation 1 Insert Sim card 2 Connect DC adaptor to GPRS modem as well serial cable provided to PC com port NOTE Please make sure there is no conflict port with the GPRS modem SMS SERVER Software Installation 1 Click on exe for installation ...

Страница 82: ...r Conversion Corporation Web SNMP Cards Page 82 UPS Management 2 Once installed the icon would appear on the tool bar 3 Right click on the SMS server icon and check modem status 4 SMS Server Software Configuration ...

Страница 83: ...ce Port NetAgent SMS Server port that use for local connection Service account Account authentication for sending SMS Leave blank if no such setting Service password Password authentication for sending SMS Leave blank if no such setting To send SMS when event occurs Yes or No 3 Enter mobile number to receive event by SMS 4 Select the event that needs to be send 5 Click Apply ...

Отзывы: