background image

IMPORTANT SAFETY INFORMATION

GENERAL SAFETY WARNINGS

Read all safety warnings and instructions. Failure to follow the warnings and instructions may 

result in electric shock, fire and/or serious injury. Save all warnings and instructions for future 

reference. 

The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible 

conditions and situations that may occur. It must be understood by the operator that common sense and 

caution are factors which cannot be built into this product, but must be supplied by the operator. Read 

carefully and understand all 

ASSEMBLY AND OPERATION INSTRUCTIONS

 before operating. Failure 

to follow the safety rules and other basic safety precautions may result in serious personal injury.

Gasoline fuel and fumes are flammable, and potentially explosive. Use proper fuel storage and handling 

procedures. 

DO NOT

 store fuel or other flammable materials nearby.

Have multiple ABC class fire  extinguishers nearby.

Operation of this equipment may create sparks that can start fires around dry vegetation. The operator 

should contact local fire agencies for laws or regulations relating to fire prevention requirements.

Set up and use only on a flat, level, well ventilated surface.

Wear ANSI-approved safety goggles and heavy-duty work gloves during set up.

1

Use only oil and fuel recommended in the “Specifications” section of this manual.

DO NOT

 transport the Generator with the Generator running

DO NOT

 sit or stand on this machine.

DO NOT

 tilt the machine while the Generator is running.

Wear ANSI-approved safety goggles, hearing protection, and heavy duty work gloves during use.

Parts, especially exhaust system components, get very hot during use. Stay clear of hot parts.

DO NOT

 cover the Generator during operation.

OPERATING PRECAUTIONS:

Carbon Monoxide Hazard Using an generator indoors CAN KILL YOU IN MINUTES. 

Generator exhaust contains carbon monoxide. This is a poison you cannot see or 

smell.

NEVER

 use inside a home or garage, 

EVEN IF

 doors and windows are open. Only use 

OUTSIDE

 and far 

away from windows, doors, and vents. 

Keep all safety guards in place and in proper working order at all times. 

Содержание 65038

Страница 1: ...INTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 65038 65038 1 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Страница 2: ...peration of this equipment may create sparks that can start fires around dry vegetation The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements Set up and use only on a flat level well ventilated surface Wear ANSI approved safety goggles and heavy duty work gloves during set up 1 Use only oil and fuel recommended in the Specifications sectio...

Страница 3: ...cancer and birth defects or other reproductive harm California Health Safety Code 25249 5 et seq When spills of fuel or oil occur they must be cleaned up immediately Dispose of fluids and cleaning materials as per any local state or federal codes and regulations Store oil rags in a bottom ventilated covered metal container Before use check for misalignment or binding of moving parts breakage of pa...

Страница 4: ... safely or correctly DO NOT fill fuel tank to the top Leave a little room for the fuel to expand as needed Wipe up any spilled fuel and allow excess to evaporate before starting generator To prevent FIRE do not start the generator while the smell of fuel hangs in the air CAUTION This generator is not intended to power sensitive electronic equipment without the addition of an appropriate line condi...

Страница 5: ...he power lines and kill or injure utility workers working on the lines GENERATOR PRECAUTIONS 2 All connections and conduits from the Generator to the load must only be installed by trained and licensed electricians and in compliance with all relevant local state and federal electrical codes and standards and other regulations where applicable 3 The Generator must be earth grounded in accordance wi...

Страница 6: ...PARTS AND COMPONENTS 5 ...

Страница 7: ...tick back in NOTICE DO NOT run the generator with too little oil Generator will shut off if generator oil level is too low BATTERY only for 2GF 4 2 5GF 4 2 8GF 7 Check and make sure the electrolyte level of each battery is between the upper and lower lever markers 1 2 1 Upper level marker 1 Lower level marker AIR FILTER ELEMENT MAINTENANCE 1 Wipe off the air cleaner cover The air cleaner cover is ...

Страница 8: ...handle slowly conforming to its recoiling force ELECTRIC STARTER Push the generator switch to START and remain there until the generator Start CAUTION Use the generator switch not more than 5 second each time to avoid damage of the generator Try once more 10 second later after last attempt failures Once the generator starts reset the generator switch to ON 1 Preheat the generator and push back the...

Страница 9: ... proper main jet is used The output would be much lower if not adjust the jet CAUTION The generator equipped with the main jet applicable to high altitudes may be damaged seriously in area below specified altitude because its mixture ratio is too thin output drops and the generator overheats for operation in low altitude area In the case ask your dealer to recover the generator to its normal techn...

Страница 10: ...SPECIFICATIONS WIRING DIAGRAM 1 3GF 2GF 1 3 2GF 1 3GF 3 1 5GF 3 2GF 2 2GF 3 2 5GF 3 9 ...

Страница 11: ...out the generator oil in the crankcase rapidly and entirely 1 Turn off the oil filler cap and drain plug to drain generator oil thoroughly Reinstall the drain plug and screw in securely 2 Fill the specified generator oil to the upper lever mark 3 Reinstall the oil filler cap SPECIFICATIONS 10 ...

Страница 12: ...et and Rubber on the frame with bolts and nuts engine Fix the Axle on the frame with bolts and nuts 2 Fix the left and right Wheels on the frame with splint pin Fix the Handles on the frame with bolts and nuts Install the Pin Roll Pin Roll Cap and Back Spring on the frame 11 ...

Страница 13: ...x 5 Install the air cleaner filter and cover to original position 6 Washing of Deposit Cup Set the fuel switch at OFF remove the deposit cup and O ring Wash them in non flammable or high flash point cleansing solvents and then dry them up at last carry out re installation Set the fuel switch to ON and check for leaks After reinstalling the deposit cup check it for leakage and make sure the area ar...

Страница 14: ...ing the throttle fixing screw under the engine runs at a low speed Standard idling 1500 100rpm TRANSPORT STORAGE AND REMOVAL FROM STORAGE Transport with the fuel switch turned off Transport or store the engine it is cool so as to avoid getting burns or fire If the engine is not kept in use for a long time be sure to store it properly 1 Make sure the storage area is dry and free of dust 2 Make sure...

Страница 15: ...TROUBLESHOOTING 14 ...

Страница 16: ...th wet hand Make sure there is no spilled fuel outside the engine and that the spark plug isn t dipped with fuel To prevent fire keep sparks for away from the spark plug mount hole Once you find any of above problems contact the authorization entitle to the dealer of the privilege helps for you 15 ...

Страница 17: ...CRANKCASE ASSEMBLY 16 ...

Страница 18: ...CRANKCASE COVER ASSEMBLY 17 ...

Страница 19: ...CYLINDER HEAH AND HEAD COVER ASSEMBLY 18 ...

Страница 20: ...CRANKSHAFT PISTON CONNECTING AND BALANCING SHAFT 19 ...

Страница 21: ...OMBINATION OF CAM SHAFT AND VALVE ROCKER 20 ...

Страница 22: ...CARBURETOR ASSEMBLY 21 ...

Страница 23: ...FULL TANK ASSEMBLY 22 ...

Страница 24: ...AIR CLEANER ASSEMBLY 23 MUFFLER ...

Страница 25: ...RECOIL STARTER 24 ...

Страница 26: ...REGULATING CONTROL SYSTEM ASSEMBLY 25 ...

Страница 27: ...FLYWHEEL IGNITION ASSEMBLYY 26 IGNITON COIL ...

Страница 28: ...27 STARTING MOTOR ASSMBLY ...

Страница 29: ...GENERATOR ASSEMBLY 28 ...

Страница 30: ...CONTROL PANEL ASSEMBLY 29 ...

Страница 31: ...FRAME ASSEMBLY 30 ...

Страница 32: ... STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial number r...

Отзывы: