Xtreme Power 5850GPH Скачать руководство пользователя страница 8

7

START-UP AND OPERATION

PUMP DISCHARGE POSITION

Step 1:

 Remove 

ALL

 plumbing attached to pump. 

Remove pump from base (if applicable). 

Step 2:

 Remove strainer housing.

 Disengage and lift off strainer cover.

 Remove strainer basket.

 Lift up on strainer ‘C’ clip and remove. 

 Slide strainer housing forward and remove. 

Step 3: 

Press positioning button located on pump housing and rotate discharge port to desired position.

Step 4: 

Assemble the pump by following the above directions in the reverse manner. 

PRIOR TO START-UP

Fill strainer housing with water to suction pipe level. 

NEVER

 operate the pump without water. Water acts 

as a coolant and lubricant for the mechanical shaft seal. 

NEVER

 run pump dry. Running pump dry may damage seals, causing leakage and flooding. Fill strainer 

housing with water before starting motor.

DO NOT

 add chemicals to pool/spa system directly in front of pump suction. Adding undiluted chemicals 

may damage pump and voids warranty. 
 Before removing strainer cover:

1. STOP PUMP 

before proceeding.

2. CLOSE VALVES

 in suction and outlet pipes.

3. RELEASE ALL PRESSURE

 from pump and piping system. 

 If pump is being pressure tested, be sure pressure has been released before removing strainer cover. 

PRIMING THE PUMP

Clean and lubricate strainer cover O-ring with “Jack’s 327” each time it is removed. 

Clean and inspect O-ring; re-install on strainer cover. 
Replace strainer cover on strainer housing; turn clockwise to tighten cover. 

NOTE: Tighten strainer 

cover by hand only (no wrenches) ¼ turn. 

Open all valves before starting system.

Release all air from filter and piping system.

With suction and outlet valves open and water source higher than the pump and flowing, pump will 

prime itself. 

If pump does 

NOT

 prime within ten minutes, stop motor and determine cause. Be sure all suction and 

discharge valves are open when pump is running. See Troubleshooting Guide. 

EXPLOSION HAZARD:

 Purging the system with compressed air can cause components to explode, 

with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume 

blower when air purging the pump, filter, or piping.

Allowing the pump to freeze will void the warranty. 

DO NOT

 use anti-freeze solutions (except propylene glycol) in your pool/spa system. Propylene glycol 

is non-toxic and will not damage plastic system components; other anti-freezes are highly toxic and may 

damage plastic components in the system. Gravity drain system as far as possible. 

Содержание 5850GPH

Страница 1: ...ERATING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNE...

Страница 2: ...and do a better job at the capacity for which it was intended DO NOT use this equipment for a purpose for which it was not intended Industrial or commercial applications must follow OSHA requirements...

Страница 3: ...or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cover Limb Entrapment A limb inserted into an opening...

Страница 4: ...DO NOT operate pool and spa circulation system unless filter air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulati...

Страница 5: ...l types and sizes including in floor cleaning systems solar heating systems water features It features full flow hydraulics allowing greater flow at a lower cost of operation It allows you save electr...

Страница 6: ...RAINER POOL SUCTION BALL VALVE WATER LINE 1 Pump Mounting Install pump on a firm level base or pad to meet all local and national codes Fasten pump to base or pad with screws or bolts to further reduc...

Страница 7: ...the risk of electric shock DO NOT use an extension cord to connect unit to electric supply Provide a properly located electrical receptacle Before working on any electrical equipment turn off power s...

Страница 8: ...g pressure tested be sure pressure has been released before removing strainer cover PRIMING THE PUMP Clean and lubricate strainer cover O ring with Jack s 327 each time it is removed Clean and inspect...

Страница 9: ...sion in hot water can induce hyperthermia 2 Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subsequently result in drow...

Страница 10: ...of non granulated liquid type soap DO NOT use petroleum or silicone lubricants as these can contribute to seal leakage 10 Press the new rotating portion of the seal assembly onto the impeller stem wit...

Страница 11: ...TROUBLESHOOTING 10...

Страница 12: ...ket regularly DO NOT strike basket to clean Inspect strainer cover gasket regularly and replace as necessary Keep motor clean Insure air vents are free from obstruction Occasionally shaft seals must b...

Страница 13: ...RESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER...

Отзывы: