background image

XVT

600,

 

XVT

800,

 

XVT

1200,

 

XVT

1500

 

USER’S

 

MANUAL

 

UNINTERRUPTIBLE

 

POWER

 

SUPPLY

 

(UPS)

 

 

SPECIFICATIONS

 

  

120V Model 

XVT-600 

XVT-800 

XVT-1200 

XVT-1500 

INPUT 

Voltage 

94V-144V ± 5V 

Capacity VA (W) 

600 VA (360 W) 

800 VA (480 W) 

1200 VA (720 W) 

1440 VA (900 W) 

Frequency 

60HZ ± 5Hz 

OUTPUT 

Voltage  

105-134 VAC (120V ± 12%) 

Waveform 

Pure Sine Wave (Typical) 

Frequency 

AC mode-follow utility Battery mode 60 ± 0.5Hz 

Transfer Time 

4ms (Typical) 

Surge Protection 

320 Joules 

Input Protection 

Compliance with IEEE 587 

Short Circuit 

Breaker 

BATTERY 

Battery Type 

Sealed, Maintenance-free lead acid 

Battery Qty & 
Size 

(1) 12V 7AH 

(1) 12V 9AH 

(2) 12V 7AH 

(2) 12V 9AH 

Recharge 

less than 10 hours to 90% capacity 

Backup Time 
(full load) & (half 
load) 

3 min (full load) 

 6 min (50% load) 

Charge Current 

1.5A (Max) 

PHYSICAL 

Dimensions 

W x D x H 

(inches) 

W x D x H 

(inches) 

W x D x H 

(inches) 

W x D x H 

(inches) 

Product 
Dimensions 

3.7” x 14.6” x 

6.2” 

3.7” x 14.6” x 

6.2” 

4.9” x 16.9” x 

8.7” 

4.9” x 16.9” x 

8.7” 

Shipping 
Dimensions 

6.1”x 16.2”x 

10.2” 

6.1”x 16.2”x 

10.2” 

7.5”x 18.9”x 

12.8” 

7.5”x 18.9”x 

12.8” 

Product Weight 

15.3 lbs. 

16.8 lbs. 

27.6 lbs. 

31.3 lbs. 

Shipping Weight 

17.6 lbs. 

19.2 lbs. 

29.8 lbs. 

32.4 lbs. 

Line Cord (6 ft.) 

NEMA 5-15P 

Receptacles 

(6) NEMA 5-15R (3-SURGE PROTECTED/3-UPS) 

Communication 
Interface 

USB Communications 

Bezel Color 

Brushed Metallic Outer / Black Inner 

Included in box 

PowerManager CD, USB cable, Manual 

ENVIRONMENT 

Operating 
Temperature 

0-35ºC 

Humidity 0%-90% 

Audible Noise 

<45dB 

Altitude 

5000 ft. (1500 m) above sea level 

WARRANTY 

Warranty 

Two years electronics / One year batteries 

APPROVALS 

North America 

UL cUL FCC 

 

[17]

 

Содержание XVT?600

Страница 1: ...Xtreme Value Tower Series XVT User s Installation Manual Xtreme Power Conversion Corporation...

Страница 2: ...ION 5 DETERMINING THE POWER REQUIREMENTS OF YOUR EQUIPMENT 7 HARDWARE INSTALLATION GUIDE 7 QUICKSTART SOFTWARE INSTALLATION GUIDE 9 REPLACING THE BATTERY 14 DEFINITIONS FOR LED INDICATORS 15 ALARMS 15...

Страница 3: ...ts for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment...

Страница 4: ...enance No user serviceable parts inside CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION UPS must be connected to an AC power ou...

Страница 5: ...Interactive Automatic Voltage Regulation AVR UPS technology Under normal AC power operation the input power flows through the AVR circuit regulating the incoming AC power to the output of the UPS and...

Страница 6: ...ng a power failure Power Switch Can be used as a master on off switch for equipment connected to the battery powered outlets Power On Indicator This LED is illuminated when the utility condition is no...

Страница 7: ...ctors can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 85 of the UPS capacity HARDWARE INS...

Страница 8: ...e UPS on 6 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC wall outlet and there is acceptable AC voltage present the battery will automatically recharge Charging i...

Страница 9: ...de the box 2 Insert one end of the USB Cable into the UPS and the other into a USB port on your computer 3 Insert the CD into your computers CD drive 4 When the software interface requests a serial nu...

Страница 10: ...T 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Input user name company name and serial number into the software interface Note the serial number is on the CD software jacket Choose installation...

Страница 11: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Choose software language and click Next Software will install automatically 11...

Страница 12: ...XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Choose Will you run Powermanager II right now and click Finish After the UPS switches on please choose the System Setting tab from the...

Страница 13: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Click Local UPS and choose USB click OK The UPS is now connected and in normal operation 13...

Страница 14: ...em voltage is only 12VDC and 24VDC the battery can present a high risk of short circuit current and electrical shock The short circuit current capability of the battery is sufficient to burn wire or t...

Страница 15: ...Power OFF OFF FLASH On Battery ON Charge ON Overheat Low Battery Overload Protection Short Circuit Note means any situation ALARMS Alarm Indication Unit Status Buzzer every 5 sec DC start Buzzer every...

Страница 16: ...east 4 hours The battery is defective Contact Xtreme Power Conversion about replacement of batteries The UPS will not turn on The on off switch is designed to prevent damage by rapidly turning it off...

Страница 17: ...load half load 3 min full load 6 min 50 load Charge Current 1 5A Max PHYSICAL Dimensions W x D x H inches W x D x H inches W x D x H inches W x D x H inches Product Dimensions 3 7 x 14 6 x 6 2 3 7 x...

Страница 18: ...ode Green LED on Orange LED on Red LED off no beep Charging Battery Orange LED on Battery Mode Green LED and Orange LED off Red LED flash buzzer slow beep Battery Low Green LED and Orange LED off Red...

Страница 19: ...ician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material...

Страница 20: ...a the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjec...

Страница 21: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS 21...

Отзывы: