There are two springs on the rear of the condenser water tank
guide.
1. Release the screw on the spring hook.
2. Take off the spring hook, and then pull out the opposite spring
hook from the hole in the condenser
water tank guide.
3. Replace with a new spring in reverse
order.
4. Repeat these steps for the other
spring.
Spring Replacement
closed position.
5. Replace the clean filter and close the filter guard.
6. To clean the condenser filter, lift up on the rear filter from the
middle bar slightly and then angle the filter outwards from the
bottom and remove.
7. Use the same cleaning procedure as in steps 3-5 above.
8. To replace the condenser filter, place the top of the filter in the
guide and slide the filter up until the bottom of the filter clears
the frame. Then push the bottom of the filter into the guide and
let the filter gently fall inside the guide.
NOTE: For effective cooling, clean the filter at least every 2 weeks.
DO NOT operate without the filter installed
WARNING
DO NOT operate the unit with a damaged cord or
plug, after the unit malfunctions, or if the unit has
been dropped or damaged.
WARNING
Figure 9 – Spring Replacement