XtraVac CM300 Chamber Machine Operation and Parts Manual
XtraVac Packaging Machines
419 E. 11th Ave. North Kansas City, MO 64116 USA
CM300 Chamber Machine
+
+1 800 728 2999 [email protected]
11
3.1 Memory set display(A): display the current memory set (e.g. ”3” means the 3
rd
set)
3.2 Vacuum time display(B): display the current setting of vacuum time (unit: 1/s)
3.3 Nitrogen filling time display(C): display the current setting of nitrogen filling time
(unit: 1/s)
3.4 Sealing time display(D): display the current setting of sealing time (unit: 0.1/s)
3.5 Cooling time display(E): display the current setting of cooling time (unit: 0.1/s)
3.6 Memory release key(F): press key for modifying memory function
3.7 Memory input key(G): press key for locking memory function
3.8 Reserved key(H): key reserved for further use.
3.9 E-stop key(I): make timing function stop, and release the upper lid.
3.10 Time increase key(J): press key for time adding
3.11 Time decrease key(K): press key for time reducing
3.12 Power switch(057): switch for turning on the electric power
3.13 Vacuum gauge(058): display the vacuum situation
3.14 Sequence of trial run:
3.14.1 Connect the power.
3.14.2 Packaging test:
(A) Test the sealing temperature and adjust the sealing time in accordance with Chapter 3
page 10(D).
(B) Test the vacuum degree and adjust the vacuum time in accordance with Chapter 3 page
10(B).
3.14.3 If everything is OK, operate the machine according to the instructions in Chapter 4
for normal production.
Содержание CM300
Страница 1: ......