23
E-mail: [email protected]
Website: www. Xtramus.com
XTRAMUS TECHNOLOGIES
®
C. NuTAP-311 HyperTerminal Command
– mode
Command Descriptions
– mode
mode
show
The
mode show
command allows you to view NuTAP-311
’s redirect mode
(
aggregation
,
segregation
, or
multi-mirror
) settings.
set
The
mode set [aggregation | segregation | multimirror] <m0 | m1>
command
allows you to set NuTAP-311
’s redirect mode for
Monitor Port M0/M1
. For example, to
set NuTAP-311 Monitor Port M0 to aggregation redirect mode, please input the
command
“
mode set aggregation m0
”.
D. NuTAP-311 HyperTerminal Command
– monitor
Command Descriptions
– monitor
monitor
show
The
monitor show
command allows you to view header and media type for all
NuTAP-311
’s ports (Network Port A0/A1 and Monitor Port M0/M1).
header
The
monitor [m0 | m1 | port=all] header [da | sa | id | dip | sip | dport | sport | mtu]
<Parameter>
command allows you to configure NuTAP-311
’s
Monitor Ports M0/M1
.
The configuration options available includes:
DA:
Destination Address
SA:
Source Address
ID:
ID
DIP:
Destination IP Address
SIP:
Source IP Address
DPORT:
Destination Port
SPORT:
Source Port
MTU:
Maximum Transmission Unit
For example, to set NuTAP-311 Monitor Port M0
’s destination port to port 9, please
input the command
“
monitor m0 header dport 0009
”. The formats for each available
configuration option are listed down below:
DA/SA:
XX-XX-XX-XX-XX-XX
ID:
XXXX
DIP/SIP:
XXX.XXX.XXX.XXX
DPORT/SPORT:
XXXX
mode
The
monitor [m0 | m1 | port=all] header mode
command allows you to set
the combinations of headers that will be added to packets to/from designated
Monitor Port (
MAC
,
ID
,
Timestamp
,
IP
,
Port
,
Fragment
). For example, to add
the header with ID and IP to packets to/from Monitor Port M0, please input the
command
“
monitor m0 header mode id+ip
”
reset
The
monitor [m0 | m1 | port=all] header reset
command allows you to reset
all settings made to the specific Monitor Port. For example, to reset all settings
done for Monitor Port M0, please input the command
“
monitor m0 header
reset
”.
Содержание NuTAP-311
Страница 1: ...NuTAP 311 User s Manual USM Ver 1 0 ...