Accessing the FastTrace 'User Settings' menu:

Setup parameters and configuration options for the FastTrace can now be modified via the 

User Settings

 menu. To

display the menu:

 

Go to the 

Connection

 menu and click the 

Installer Menu 

option

For a new FastTrace, a message will appear asking the user to accept the Factory Default settings.
Click 

YES 

to this question.

The menu consists of a number of major categories, some with a number of sub-categories and option choices.
Selection of a particular category can be expanded by double-clicking on the menu item.

Once the configuration is complete, all changes can be saved using the 

Save all changes

 button. When saved, the

changes are downloaded to the FastTrace memory for permanent storage.

NOTE

:  The setup program will not allow invalid parameters to be saved. For example, should you receive a message

asking for a correct Ethernet Gateway address to be entered, either enter the correct value or delete the invalid entry.

Setting the Operational Parameters:

The FastTrace is factory configured with ‘typical’ operating
values, but to use the FastTrace in an operational
environment, it's configuration must be modified to use the
site names, phone numbers or network addresses that match
the real network.

Once the FastTrace settings have been configured, the
ADPRO FastTrace PC Viewer settings must be updated to
match.

Setting the ADPRO FastTrace PC Viewer Telephone
(Dial-up) Connection

The basic information needed to use a telephone (dial-up)
connection is entered via the 

Database / Administration /

Site Details

 menu

:

Site ID

9 characters (max)

Password

8 characters (max)

Modem Type

Select from the list (Note
different modem types must
be installed via the Windows
Control Panel)

PC Viewer Settings for a Network Connection

The ADPRO FastTrace PC Viewer software will require some basic information in order to connect to any FastTrace site
via a network connection. The minimum information that must be configured in each FastTrace is shown below.

To enter the information, go to 

Database / Administration / Site Details

 then select the 

Edit

 option.

Site ID

9 characters (max)

Password

8 characters (max)

IP Address

The TCP/IP network address assigned to each FastTrace (this address is normally assigned by
the network manager)

Once the basic connection details have been configured and

saved

, the FastTrace is ready to connect via the operational

network.

Null-modem cable wiring:

Should it be necessary to use a null-modem cable that is longer
than that supplied with the FastTrace, use the diagram shown to
make a longer cable.

Содержание ADPRO FastTrace

Страница 1: ...stTrace PC Viewer setup wizard will load If autorun is not enabled find and run the CD ROM file named cdmenu exe Select the Install FastTrace PC Viewer option Follow the setup wizard instructions and accept ALL the default settings Exit from the menu when finished but leave the CD ROM in the drive NOTE If using the Windows NT system on the PC please refer to the IMPORTANT NOTES section on Page 4 C...

Страница 2: ...d FT2222 Connection Type PSTN Transmitter type FastTrace Hunt Group Hunt Group 0 Phone number 0 Optional Network Connection Settings If using the PC s network port instead of the serial port a crossover network cable Cat 5 must be used between the PC and the FastTrace Note this cable NOT supplied The factory TCP IP network address for the FastTrace is 192 168 1 1 The factory subnet mask address is...

Страница 3: ...n must be modified to use the site names phone numbers or network addresses that match the real network Once the FastTrace settings have been configured the ADPRO FastTrace PC Viewer settings must be updated to match Setting the ADPRO FastTrace PC Viewer Telephone Dial up Connection The basic information needed to use a telephone dial up connection is entered via the Database Administration Site D...

Страница 4: ...nections are required or the unit becomes disconnected for any reason then the serial cable must be unplugged for at least 10 seconds This procedure will ensure that the FastTrace stops trying to reconnect and locking out the correct connection attempts by the PC Viewer software LED Switch When power is first applied to the FastTrace unit the red LED on the front of the unit will be on Within a fe...

Отзывы: