TROUBLE SHOOTING
Warning: Before any maintenance or repair work, you must cul off the power supply and
ensure that the air tank is pressure-free, otherwise it is very easy to cause injury!
Problem
The motor does
not start and
without
any noise
The motor does
not start or
starts slowly,with
a humming noise
The overload
protector cuts
off the power
repeatedly
Pressure drops
in the tank
The exhaust
gas has a
high humidity
The motor does
not stop
Machine with
High vibration
Can not reach
the max working
pressure
Possible cause
Solution
No Power supply
Pressure switch is off
Under overload protection
Pressure switch faulty
Check the plug and the power supply
turn on the pressure switch
Press the red reset button to start afler
the machine cooled down
Replace the pressure switch
Stator faulty
Replace the stator
Low voltage supply
Place the air compressor in a
well-ventilated place
Short circuit or open circuit
of motor coiling
Contact dealer
Check valve or pressure
switch faulty
Low voltage supply
Poor ventilation,
too high temperature
Wrong installation of fan
Contact dealer
Check the input voltage, can not 10%
lower than the rated voltage
lower
Check
!han
the
the
input
rated
voltage
vol t age
can not 10%
Check the fan and install it in
the correct direction
Air leaks at connections
Drain valve is open or loose
Check each connection,tighten
leaky connection
Tighten the drain valve
Air leaks at check valve
Remove and clean, if still not work,
Replace the check valve
A lot of water in the tank
The workin environment
with too hig � humidity
Drain the water in the tank
Move the air compressor to a place with
low humidity,or use an oil-water separator
Pressure switch faulty
Air leakage, can not reach
the max pressure
Replace the pressure switch
Check and tighten the leaky connection
Check and tighten
Loose fasteners
The interna! parts of the air
compressor are aging or damaged Replace foot or shock pad
Cushion foot or shock
pad damaged
Drain valve is open or loose
Replace aging or damaged parts
Tighten the drain valve
Air filter blocked
Air leakage
Poor valve function or foreign
matter or air leakage
Clean or replace the filter element
Check and tighten
Clean or replace
Excessive wear of piston rings
Replace the piston ring
Содержание XT2008