Avoid the power cord damage.
-
Disconnect the pump power cord from a power supply prior to removing the pump from the pumped
liquid, any manipulation or maintenance.
-
Never carry or hang the pump by its power cord or the float switch cord.
-
Any intervention, repair or modification shall be carried out by an authorized XTline service
personnel only.
-
Avoid reducing the liquid flow rate of the output hose or pipe (for example by unintentional bending)
or damaging the hose with sharp objects.
-
Make sure no abrasive material (sand) gets into the pumped liquid during the operation.
-
Do not let the pump in the pumped liquid when not operating for a longer period of time.
-
Do not let the pump in the pumped liquid in temperatures below 0°C. If the pumped liquid becomes
frozen, never defrost with an open flame or any direct heat source. Transfer the pump to a room temperature
area and let defrost.
Shutdown
1.
Turn the pump off, remove from the pumped liquid and submerge to a clean water container.
2.
Turn on and let operate to clean the inner parts.
3.
Turn off and remove the pump from the water container.
7. Cleaning and Maintenance
Disconnect the tool power cord from a power supply prior to any manipulation.
-
Keep the tool clean. It is necessary to appropriately clean the pump from any sedimented material
after each operation.
-
Check regularly to prevent any damage or wear of the tool parts.
-
Do not modify the pump for other purposes in any way.
Troubleshooting
defect
cause
redress
The pump does not start when
the engine is switched on, the
engine is silent
No mains voltage
Check power supply, circuit
breaker, current protection
Faulty socket
Please use a different socket
cable defect
Check the cables or replace them
Float switch is blocked
Release the float switch and set it to the
desired level
Activate thermal protection
Allow the pump motor to cool down
and remove the cause of the
activation
The pump does not
start when the ignition is
switched on, the engine
buzzes
The impeller is locked
Remove the stand and clean the area of
the pump impeller
Rotor glued in sealing
positions
Rotate the impeller
Faulty capacitor
Contact your XTline Authorized
Service Center
The pump will start, but its
performance is small and the
operation is noisy
The discharge hose or suction
system is clogged
Clean the hose or impeller
space
Worn impeller
Have a replacement in an
authorized service center
Fluctuating mains voltage
Stabilize network voltage
Water in the pump terminal or
motor winding area
Damaged mechanical seal or
sealing rings
Contact your XTline Authorized
Service Center