damaged.
Hand pulse lost its function.
(No pulse displayed on
monitor)
1. Hands not on the hand pulse sensors or only one hand on
sensor.
2. The connector of HANDPULSE W/WIRE and Console
not connected properly.
3. The wires got damaged when connecting the
HANDPULSE W/WIRE and Console.
4. Hand pulse board is broken.
1. Two hands hold the hand pulse.
2. Connect the cable again.
3. Replace with new cable.
4. Replace console or Hand pulse board.
Wireless lost its function.
(No pulse displayed on
monitor)
1. Chest belt not worn properly.
2. Distance is too far and exceeds range of receiver.
3. Chest belt battery is weak or dead.
1. Check chest belt has proper contact with skin
and is oriented correctly.
2. User chest belt in front of console within 3
feet.
3. Replace with new lithium battery type is
CR2032.
Chest belt too close to the
treadmill.
Weak battery.
Replace with new lithium battery with type
CR2032.
Tread belt does not run in
center.
Tread belt tension not even across tread belt.
See treadbelt adjustment
(see Appendix A)
Tread belt hesitates while
being stepped on.
Insufficient lubricant on tread belt.
Tread belt tension insufficient
See treadbelt lubrication
(see Appendix B)
Tension Belt (see Appendix A )
Black particles collecting
Drive belt is breaking in.
Vacuum under treadmill periodically.