![XtendLan XL-ICA-H662 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/xtendlan/xl-ica-h662/xl-ica-h662_users-manual-for-web-management_3724119022.webp)
19
Please refer to the following sheet for detailed information.
Parameter Function
Max
connection
It is the max Web connection for the same device. The value ranges from 1
to 20. The default setup is 10.
TCP port
The value ranges from 1025 to 65535. The default value is 37777. You can
input the actual port number if necessary.
UDP port
The value ranges from 1025 to 65535. The default value is 37778. You can
input the actual port number if necessary.
HTTP port The value ranges from 1025 to 65535. The default value is 80. You can
input the actual port number if necessary.
RTSP port
Usually, the default value is 554. You do not need to input again if you
are using the default value. When you are using QuickTime (Apple
browser) or VLC play real-time video, you can use the following format
to play. The Blackberry also supports this function.
Real-time monitor bit stream Url format. Please specify the channel
number, bit stream type in the Url if you are requesting real-time
monitor bit stream Rtsp stream media service. You still need to
provide user name or password if it has verification information.
When you are using Blackberry phone to access, the bit stream mode
shall be H.264B, resolution is CIF and the audio shall be disabled.
The Url format is shown as below:
rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0
You need to input the following items manually.
Username/password/IP/port/subtype.
The IP is device IP and the port default value is 554. You can leave it in
blank if it is the default value. The channel number begins with 1.
subtype
:
bit stream type
,
main stream is 0
(
subtype=0
)
and extra
stream is 1
(
subtype=1
)
.
You do not need to input the user name and password if you do not need
the verification. Such as:
Main stream
:
rtsp://ip:port/cam/realmonitor?channel=1&subtype=0
HTTPS
Enable
It is to enable HTTPs communication service control. If you enable this
function, you can use https://ip:port to login the device. In data encryption
protection mode, you can use https://ip to login if you are using the default
port.
HTTPS
Port
The HTTPs communication port value ranges from 1025 to 65535.