background image

15 

 

5

 

Web Operation 

 

This series network camera product supports the Web access and management via PC. 

Web includes several modules: monitor channel preview, system configuration, alarm and etc. 

5.1

 

Network Connection 

 

Please follow the steps listed below for network connection. 

 

Make sure the network camera has connected to the network properly. 

 

Please set the IP address, subnet mask and gateway of the PC and the network camera 

respectively. Network camera default IP address is 192.168.1.108. Subnet mask is 255.255.255.0. 

Gateway is 192.168.1.1 

 

Use order ping ***.***.***.***(* network camera address) to check connection is OK or not. 

5.2

 

Login and Logout 

 

Open IE and input network camera address in the address bar. See Figure 5-1. 

 

 

 

Input your IP 

address here 

 

 
 

 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

 

 

Figure 5-1 

 

The login interface is shown as below. See Figure 5-2. 

Please input your user name and password. 

Default factory name is admin and password is admin. 

Note: For security reasons, please modify your password after you first login.

 

Содержание XL-ICA-206M2IR-36

Страница 1: ...i XL ICA 206M2IR 36 IP camera User manual ...

Страница 2: ...er cut off device during the installation connection Always follow the instruction guide the manufacturer recommended 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment This series network camera should be installed in a cool dry ...

Страница 3: ...ch dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device Please put the dustproof cap to protect the CCD CMOS component when you do not use the camera 7 Accessories Be sure to use all the accessories recommended by manufacturer Before installation please open the package and check all the components are includ...

Страница 4: ... 1 Components 8 2 2 Framework and Dimension 8 3 Device Installation 10 3 1 Installation Steps 10 3 2 Restore Factory Default Setup Introduction 12 4 Quick Configuration Tool 13 4 1 Overview 13 4 2 Operation 13 5 Web Operation 15 5 1 Network Connection 15 5 2 Login and Logout 15 6 FAQ 17 Appendix Toxic or Hazardous Materials or Elements 18 ...

Страница 5: ... Support central server backup function in accordance with your configuration and setup in alarm or schedule setting Support record via Web and the recorded file are storage in the client end PC Support network storage function such as FTP Network Monitor Network camera supports one channel video data transmit to network terminal and then decode Delaying time is within 270ms network bandwidth supp...

Страница 6: ...IR CUT switch Gain Control Fixed Auto White Balance Manual Auto Exposure Mode Manual Auto PAL It ranges from 1 3 to 1 10000 NTSC It ranges from 1 4 to 1 10000 Video Compression Standard H 264 JPEG MJPEG Video Bit Rate 48k 8192kbps Bit rate is adjustable Support customized setup Video Flip Support mirror Support flip function Snapshot Max 1f s snapshot File extension name is JPEG Privacy Mask Suppo...

Страница 7: ...information maintenance upgrade and etc Restore Default Setup Built in Reset button General Parameter Power DC12V power and PoE Warning Do not connect these two power supplying sources to the device at the same time it may result in device damage Power Consumption 4 5W MAX Working Temperature 10 60 Working Humidify 10 90 Dimensions mm Φ 113 86 Weight 280g Excluding box Installation Fixed on the wa...

Страница 8: ...CTV Sub Stream Enable Enable Bit stream type General Encode mode H 264B Resolution CIF 352 288 Frame Rate FPS PAL 25 NTSC 30 Bit Rate Type CBR Recommend ed Bit 192 1024Kb S Bit Rate 1024 I Frame interval 50 Snapshot Snapshot Type General Image Size 1080P 1920 1080 Quality Better Interval 1s Video Overlay Privacy Mask Disable Channel Title Enable Time Title Enable Path Snapshot Path C PictureDownlo...

Страница 9: ...nate DNS 8 8 8 8 Enable ARP Ping set device IP address service Enable Connection Max Connection 10 TCP Port 37777 UDP Port 37778 HTTP Port 80 RTSP Port 554 Enable HTTP Disable HTTPs Port 443 PPPoE Enable Disable Username none Password N A DDNS Server Type Disable CN99 DDNS Server IP none Server Port 80 Domain Name none User none Password Update Period 10 minutes IP Filter Trusted sites Disable SMT...

Страница 10: ...161 Read Community public Write Community private Trap Address N A Trap Port 162 SNMP Version SNMP v1 Disable SNMP v2 Disable SNMP v3 Disable Bonjour Enable Enable Server Name Device factory SN Multicast Multicast Address 239 255 42 42 Port 36666 QoS Real time Monitor 0 Command 0 Event Video detect Motion Detect Enable Disable Anti dither 5 seconds Sensitivity 3 Record Channel Enable Record Delay ...

Страница 11: ...cord 5 seconds Disk Full Overwrite Record Mode Auto Bit Stream Main Stream System General Local Host Device No Device MAC address Language English Date and time Date Format Y M D Time Format 24H Time Zone GMT 08 00 System Time Sync DST Disable DST Type Week Start Time 00 00 00 of the first Sunday of the month End Time 00 00 00 of the second Monday of the month NTP Disable NTP Server clock isc org ...

Страница 12: ...gure 2 1 Please refer to the following sheet for detailed information Component Component Name Component 1 Device lens Component 2 Dome body Component 3 Dome enclosure No Port Name Connector Note 4 LAN Network port Ethernet To connect to standard Ethernet 5 DC12V DC 12V power To connect to DC12V power supply 2 2 Framework and Dimension ...

Страница 13: ...9 Please refer to the following two figures for dimension information The unit is mm See Figure 2 2 and Figure 2 3 Figure 2 2 Figure 2 3 ...

Страница 14: ...nstall the device Step 3 Adjust the device installation pedestal to the proper position and then line up the three screw holes in the device pedestal to the three plastic expansion bolt holes in the installation position Put the three self tapping screws in the three plastic expansion bolts firmly Loosen the M3X8 cross recessed pan head slot screw of the pedestal to unfasten the preforming Do not ...

Страница 15: ...the other is from the side Please refer to the following figure for cable exit from the side information Figure 3 3 Please earth the GND port of the device to enhance the device reliability The GND port is near the cable exit port on the rear of the dome The GND screw uses the M2X5 pan screw ...

Страница 16: ...the gland cover Step2 Take the dome body out and then turn the top cover hard to remove Step3 Slightly press the RESET button to complete the reset function See Figure 3 5 Step4 Turn the top cover back to the original position Please make sure it reaches the original position otherwise it may result in water leakage Step5 Put the dome back to the gland cover Please refer to step4 in chapter 3 1 to...

Страница 17: ...n interface is shown as in Figure 4 1 In the device list interface you can view device IP address port number subnet mask default gateway MAC address and etc Figure 4 1 Select one IP address and then right click mouse you can see an interface is shown as in Figure 4 2 Select the Open Device Web item you can go to the corresponding web login interface Figure 4 2 If you want to modify the device IP ...

Страница 18: ...g information to login Please note the port information here shall be identical with the port value you set in TCP port in Web Network interface Otherwise you cannot login the device If you are using device background upgrade port 3800 to login other setups are all invalid Figure 4 3 After you logged in the configuration tool main interface is shown as below See Figure 4 4 Figure 4 4 For detailed ...

Страница 19: ...ateway of the PC and the network camera respectively Network camera default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 Use order ping network camera address to check connection is OK or not 5 2 Login and Logout Open IE and input network camera address in the address bar See Figure 5 1 Input your IP address here Figure 5 1 The login interface is shown as below S...

Страница 20: ... install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have installed the plug in to disable the control download Or you can lower the IE security level After you logged in you can see the main window See Figure 5 3 Figure 5 3 Please refer to the Web Operation Manual included in the resource CD for detaile...

Страница 21: ...er if you can not install the client end or can not view after the installation We recommend the win2000sp4 OS or install the client end of the low version The Active X control is blocked The display card version shall be dx8 1 or higher Network connection error occurred Invalid network setup Invalid user name or password I can not play the download file There is no player There is no DX8 1 or hig...

Отзывы: