5.2.2 Rear panel of XL-FMUX4E1
Connection Descriptions
2M Connector
BNC/75
Ω
Unbalance or RJ-45/120
Ω
Balance
Optical Transmitting
TX
Optical Receiving
RX
Power Supply
Type
DC+24V
+18VDC
~
+36 VDC, two-pin parallel receptacle
DC-48V
-36 VDC
~
72 VDC, two-pin parallel receptacle
AC220V
165
~
265VAC@50
~
60Hz, clover leaf 3-prong receptacle
Power supply:
For a model with AC power supply, AC power (165~265VAC) is supplied to the XL-FMUX4E1
through
a becoming standard clover leaf 3-prong receptacle, located on the rear of the unit. The XL-FMUX4E1
should always be grounded through the protective earth lead of the power cable in AC installations.
For a model with DC power supply, DC +24V (18~36VDC) or DC -48V (36~72VDC) is connected
to the detachable terminal block. Please take extra caution to observe the proper polarity of the DC
when wiring the connector. The XL-FMUX4E1 should always be grounded through the protective
earth lead via the frame ground connection for DC installations.
.
Hot-line phone:
4-wire handset interface detail is shown below:
Interface
Microphone
Earphone
RJ-11
2 (+)
3 (-)
1 (+)
4 (-)
Fiber optic connector:
The standard interface is FC, TX means output, RX means input.
E1 interface:
Unbalance interface: BNC connector, OUT means transmit, IN means
receive. Balance interface: RJ-45 connector, the definition is shown below:
Pin
1
2
3
4
5
6
7
8
Function
NC
TX+
Tx-
NC
NC
RX+
RX-
NC-
1 2 3 4 5 6 7 8
Note:
NC means “ No connection”
Содержание XL-FMUX4E1T
Страница 1: ...XL FMUX4E1T XL FMUX4E1 4 E1 over fiber cable PDH Fiber Optic Multiplexer User s Manual ...