![XtendLan SDOMEOAT2-SD332 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/xtendlan/sdomeoat2-sd332/sdomeoat2-sd332_user-manual_3737089005.webp)
5/16
High Speed Dome
Ver
:
1 00
PELCO D P
2400
ID
:
001
Tilereference OK
Pan reference OK
SONY FCB-EX480CP
Alarm
7 alarm input. The dome will alarm when alarm input port connect the GND. The AUX will be
closed when has alarm, and open when on alarm in. The capacitance of the relay is AC24V/1A.
The relay output:
2 relay switch AUX1, AUX2, the biggest capability is AC24V/1A. AUX1 connect with the alarm, the
master or keyboard controls AUX2.
Camera Module Setting Switch
The dome can be fit different camera, and they have different
switch.
Camera
Switch 1
Switch 2
Switch 3
Switch 4
DIP-1
DIP-2
DIP-3
DIP-4
SONY
OFF
OFF
OFF
OFF
HITACHI
OFF
OFF
ON
OFF
LG
OFF
ON
OFF
OFF
CNB-200L
OFF
ON
ON
OFF
CNB-M1560
OFF
ON
ON
ON
SAMSUNG
(SDM300/SDM330)
ON
OFF
OFF
OFF
Note: Please make sure the camera parameters are correct or the camera cannot work
or cannot work well. If this, please enter the camera menu and restore factory settings first,
then setting the parameters as request.
High Speed Dome Operation,
When Electric
When electric the dome, the version, protocol, baud rate, ID will display on the monitor, and the
dome will check automatic with vertical and level then display the specs of camera.
Example: