32 / 42
Option
Value
Explanation
ALARM NUMBER
1 ~ 4
This option allows selecting one of the 4 alarm inputs.
NONE
No action occurs during the alarm.
PRESET
The camera goes to the corresponding presetting following
the alarm (correspondence is fixed: Alarm 1 - Preset 1; Alarm
2 - Preset 2, etc.).
PATTERN
The alarm performs the corresponding pattern following the
alarm (correspondence is fixed: Alarm 1 - Pattern 1; Alarm 2 -
Pattern 2; etc.)
AUTO SCAN
The camera performs an auto scan after the alarm: the
camera performs a 360 horizontal scan operation.
RANDOM SCAN
The camera performs a random scan after the alarm: the
camera performs a random 360° scan pausing for
approximately 2” every 142°.
FRAME SCAN
The camera performs a frame scan after the alarm: the
horizontal scan is performed in the
SET SCAN
limits.
CRUISE
The camera performs a cruise after the alarm: the camera
runs a cycle of up to 30 preset positions.
ALARM ACTION
TRACKING
The camera performs a tracking operation after the alarm,
starting from the preset position associated with the alarm.
OFF
No action occurs after the alarm.
AUX1
AUX1
output is activated following the alarm: e.g. a siren.
ALARM AUX
AUX2
AUX2
output is activated following the alarm: e.g. a blinker.
ALARM CONTACT
ON/OFF
Alarm output polarity: normally open (
ON
) or normally closed
(
OFF
).
The circuit will open to generate an alarm if it is “
NC
” and will
close if it is “
NO
”.
ALARM NUMBER
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
BACK
EXIT
1
NONE
OFF
OFF
Screen 20: Alarm Settings
Table 19
If an alarm is triggered during any automatic operation of the camera (Pattern, Auto Tracking, etc.), the operation
in progress is stopped and the camera executes the action that has been set in the
ALARM ACTION
menu:
In the event of Preset action, the camera moves to the preset position. Then, if the option
PARK TIME
ACTION
is set to execute an action, the action will be executed after the
PARK TIME
period has expired.
In the event of "
TRACKING
" action, the camera executes the tracking function starting from the preset
position that has been associated with the alarm. Once the tracking action has finished, the camera
executes the action set in the option
PARK TIME ACTION
.
In the event of "
PATTERN, AUTO SCAN, RANDOM SCAN, FRAME SCAN, CRUISE
" actions, the action is
executed by the camera permanently and can only be stopped by one of the following actions: any
command sent by the operator, the 6+use of the joystick, any alarm event.