XtendLan DT607 Series Скачать руководство пользователя страница 12

-12-

Setting Ring-back Tone

If allow ring-back tone, press the call button to call monitor, a ring-back call tone can be heard 
from door station.
There are 3 ring-back call tones, 

Ringing one time

,

Ringing continuously 

and

 No ring-back 

tone

Ringing one time is default, to change the setting, please follow the steps:

Setting Night View LED Illumination Mode

There are 3 working modes for night view LED indicator, 

Normally on

,

Normally off 

and

 Auto

Auto is default, to change the setting, please follow the steps:

SETUP INSTRUCTIONS

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+, Beep

In standby mode, press 

KEY_SET

 button 

three 

times

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep+

Press 

KEY_4 

button to set 

the night view LED mode 

to

 Normally on

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep

Press 

KEY_4 

button again

to set the night view LED 

mode to

 Normally off

.

UNLOCK Indicator:ON
TALK Indicator:OFF

Buzzer

Beep, Beep,Beep

Press 

KEY_4 

button again

and again to set the night 

view LED mode to

 Auto

.

Press 

KEY_4

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep+, Beep

In standby mode, press 

KEY_SET

 button 

four 

times

.

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep+

Press 

KEY_1 

button to set 

the ring-back call tone ringing

one time.

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep, Beep

Press 

KEY_1 

button again

to set the ring-back call tone 

ringing continuously.

UNLOCK Indicator:ON
TALK Indicator:ON

Buzzer

Beep, Beep,Beep

Press 

KEY_1 

button again

and again to close ring-back

call tone.

Press 

KEY_1

• 

If setting mode has not been exited, you can change the night view LED illumination mode by pressing 

KEY4 circularly.

• 

The 

LED_NAME

 indicator will blink all the time until exit out the setting mode.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

In this step,press 

KEY_SET

 button twice to exit out the setting mode manually.

• 

If setting mode has not been exited, you can change the ring-back tone by pressing KEY1 circularly.

• 

The 

LED_NAME

 indicator will blink all the time until exit out the setting mode.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

In this step,press 

KEY_SET

 button once to exit out the setting mode manually.

Содержание DT607 Series

Страница 1: ...e and correct operation Keep this manual well for future reference RF CARD RF CARD RF CARD RF CARD RF CARD RF CARD DT607A ID S4 DT607 ID FE S1 DT607 ID FE S2 DT607F ID FE S4 DT607 ID FE S3 DT607 ID FE...

Страница 2: ...de 8 Setting Camera Resolution 10 Setting Unlock Mode 10 Setting Unlock Time 11 Setting Nameplate Illumination Mode 11 Setting Night View LED Illumination Mode 12 Setting Ring back Tone 12 Setting Ima...

Страница 3: ...8 7 6 5 12 11 12 13 13 2 2 Surface mounted Flush mounted 1 Microphone 2 UNLOCK indicator 3 CALL indicator 4 Call button 5 Nameplate 6 Front panel 7 Speaker 8 Night view LED 9 Camera lens 10 Rainy cove...

Страница 4: ...ate 4 Attach the front panel to the main unit 5 Use the special screwdriver and the screws to fix the panel 1 Drill a hole in the wall to match the size of mounting box then attach the mounting box to...

Страница 5: ...ocks L1 L2 Connect to the bus line no polarity PL External lock power input connect to the power positive power S Lock power output S Lock power output connect to the power input of locks only when us...

Страница 6: ...res the monitor with fisheye function to support The angle view is 1700 visitors in this angle view can be seen clearly and can be zoomed to see individuals up close via indoor monitor with fisheye fu...

Страница 7: ...Order Setting items Setting range Default value 1 Setting door station address 0 3 0 2 Setting door station calling mode Standard Group calling mode Standard calling mode 3 Setting camera resolution...

Страница 8: ...FF TALK Indicator OFF Buzzer Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep Beep ID 0 1st door station ID 1 2nd d...

Страница 9: ...address 02 by default Call buttonC call the monitor with address 03 by default Call buttonD call the monitor with address 04 by default Call buttonA Call all monitors in group address from 00 15 one...

Страница 10: ...ode press KEY_SET button three times UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Press KEY_1 button to set the unlock mode to Normally opened UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep...

Страница 11: ...ion mode to Normally on UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Press KEY_3 button again to set the nameplate illumina tion mode to Normally off UNLOCK Indicator ON TALK Indicator OFF...

Страница 12: ...Auto Press KEY_4 UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep In standby mode press KEY_SET button four times UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Press KEY_1 button to set the...

Страница 13: ...hen answering the call image switching reminder is not effective Zoom mode When answering the call the image will be displayed on full screen for 5 sec onds then switch to Zoom image to remind to ente...

Страница 14: ...Hz Authorizing master cards By default there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE but you should know that the master card can be authorized by users at any time That mea...

Страница 15: ...l exit out setting mode automatically If current access is controlled by door station next access switching setting is controlled by DT ACC UNLOCK Indicator Blink two times TALK Indicator OFF Buzzer B...

Страница 16: ...equence UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Show the master card of MASTER CARD DELETE again to exit UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Show the master card o...

Страница 17: ...Exit Button EB 5 The Unlock Mode must be set to 0 by default 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A 3 The jum...

Страница 18: ...on 1 2 3 4 5 6 ON DIP L2 L1 DIP Switches RF CARD PC6A AC 100 240VAC 100 240VAC DBC4A1 A B C D OFF ON Impedance switch BUS IM BUS DS PC6A AC ID 0 1st door station ID 1 2nd door station ID 2 3rd door st...

Страница 19: ...fer to Page 9 Distributor is unnecessary in full audio system and IN OUT mode is recom mended For the last monitor connected to the system DIP6 should set to ON ID 0 Code 1 DIP6 off Optional functiona...

Страница 20: ...stributor for the extension WIRING DBC4A1 A B C D RLC DBC4A1 OFF ON Impedance switch BUS IM BUS DS Code 1 DIP6 on Code 2 DIP6 on Code 3 DIP6 on Code 4 DIP6 on ID 0 RF CARD PC6A AC 100 240VAC Optional...

Страница 21: ...acture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional APPENDIX Power supply DC 24V Power consumption Standby 0 8W Working 3W Ca...

Страница 22: ...limited in the DT system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40...

Страница 23: ...23 B A C 2 2 DBC4A1 RF CARD PC6A Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 APPENDIX Star Topology Wiring Mode With DBC4A1...

Страница 24: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG DT607 V1...

Отзывы: