3.Door Station Mounting

1

2

4

3

Drill holes in the wall to match the size of 

screws and attach the rainy cover to the wall.

Attach the panel to the rainy cover

Use the screwdriver and the screw 

to fix the panel 

Connect the cable correctly 

DT601/ID Mounting

-2-

 

Lock Control Jumper: 

To select the lock type.

 

Main Connect Port:

 To connect the bus line and the electronic locks.

 

BUS: Connect to the bus line, no polarity.

 

PL: External lock power input, connect to the power positive(power +).

 

S+: Lock power(+) output.

 

S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door 
station to power the locks, if using the external power supply for the locks, the S- will not be 
connected).

Содержание DPC-D248-FR

Страница 1: ...DPC D248 R DPC D248 FR RF CARD RF CARD English User Manual 2 Wire Video Outdoor Station...

Страница 2: ...minal Descriptions 1 3 Door Station Mounting 2 4 System Wiring and Electric Lock Connection 4 5 ID Card Registration 8 6 Unlock Operations 10 7 ID Setting of Door Station 10 8 Precaustions 11 9 Specif...

Страница 3: ...crophone 93 mm 182 mm Night Light RF CARD ID card window RF CARD 30 mm 220 mm 120 mm RF CARD Camera Lens Speaker Nameplate Call Button Microphone Night Light Screws for panel mounting RF CARD 1 Parts...

Страница 4: ...T601 ID Mounting 2 Lock Control Jumper To select the lock type Main Connect Port To connect the bus line and the electronic locks BUS Connect to the bus line no polarity PL External lock power input c...

Страница 5: ...tach to the wall Attach the panel to the mounting box and use screws supplied to fix the panel Connect the cable correctly Placing Name Label AcDbMLeader ACDB_MLEADER_CLASS AcDbMLeader ACDB_MLEADER_CL...

Страница 6: ...led with Internal Power Note 1 Electronic lock of Power on to unlock type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not ti...

Страница 7: ...n as slaver unit called 8007 Panel off as slaver unit called 8008 Date format MM DD YYYY 8009 Date format DD MM YYYY 8010 Set lock mode to 0 8011 Set lock mode to 1 8021 8029 Set the lock time of 1 9s...

Страница 8: ...S L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S Device Address 3 Device Address 2 Device Address 1 Device Address 0 Basic IN OUT Wiring Mode Multi Monitors Connection Code 0 DIP 6 off 1 2 3 4 5 6 ON Code 15...

Страница 9: ...1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 3 DIP 6 on Code 1 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 2 DIP 6 on Code 0 DIP 6 on OFF ON OFF ON monitor monitor monitor monitor monitor monitor monitor monito...

Страница 10: ...user cards to be added one by one Show the MASTER CARD ADD card to exit white The color of background indicator green blink one time The color of background indicator blue Delete User Cards Notice it...

Страница 11: ...e Show the MASTER CARD ADD card to ID card window again format operation is performing The color of background indicator beep beep beep yellow The color of background indicator The color of background...

Страница 12: ...nlocked Unlocking of ID Card 7 ID Settings of Door Station The color of background indicator beep beep beep Press the Call Button 3 seconds At this time press the Call Button will to exit the setting...

Страница 13: ...e manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional Power Supply DC 24V supplied by PS4...

Страница 14: ...system Using different cables may also affect the maximum distance which the system can reach When Monitor quantity 20 Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 4...

Отзывы: