![XtendLan DPC-D247 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/xtendlan/dpc-d247/dpc-d247_user-manual_3724081005.webp)
Electric Lock Connection
Door Lock Controlled with Internal Power
connect one lock
connect two locks
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than
250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The
Unlock Mode
Parameter of Monitor must be set to 0 (by default).
EB
*
LOCK
LOCK
2
nd
1
ST
2
nd
EB
*
1
ST
Jumper position in
Connect two locks
2-3
1 2 3
BUS
PL
S1+ S2+ S-
EB
*
LOCK
BUS
PL
S1+ S2+ S-
Jumper position in
Connect one lock
2-3
1 2 3
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. Setup the
Unlock Mode
of Monitor for different lock types.
•
Power-on-to-unlock type:Unlock Mode=0 (by default)
•
Power-off-to-unlock type:Unlock Mode=1
-8-