XtendLan DPC-D244-FR Скачать руководство пользователя страница 3

••

JP/LK(Lock Control Jumper): 

To•select•the•lock•type:•see•section•4

••

Doorstation Code DIP: 

Total•4•door•stations•can•be•supported,see•section•5

••

RS485:

Used•to•update•the•program•for•door•station•

••

MIC

:•Adjust•the•volume•of•Microphone

••

SPK

:•Adjust•the•volume•of•Speaker

••

Main Connect Port:

•To•connect•the•bus•line•and•the•electronic•locks.

BUS:•Connect•to•the•bus•line,•no•polarity.

•• PL:•External•lock•power•input,•connect•to•the•power•positive(power•+).
•• S1+,•S2+:•Lock•power(+)•output,•to•connect•2•locks.
•• S-:•Lock•power(-)•output,•connect•to•the•power(-)•input•of•locks(only•when•using•the•camera•to•power•

the•locks,•if•using•the•external•power•supply•for•the•locks,•the•S-•will•not•be•connected).

3.Door Station Mounting

adjust camera angle

1

2

4

3

Drill holes in the wall to match the size of 

screws and attach the rainy cover to the wall.

Attach the panel to the rainy cover

Use the screwdriver and the screw 

to fix the panel 

Connect the cable correctly and adjust 

right angle for camera 

DPC-D244-R Mounting

-2-

Содержание DPC-D244-FR

Страница 1: ...2 Wire Intercom System RF CARD RF CARD DPC D244 R DPC D244 FR User s manual DPC D244 FR DPC D244 R ...

Страница 2: ...crophone 90 mm 28 mm 176 mm 220 mm 119 mm ID card window Camera Lens Speaker Nameplate Call Button Screws for panel mounting Microphone RF CARD RF CARD 1 Parts and Functions 2 Terminal Descriptions BUS PL S1 S2 S MIC adjustment Lock Control Jumper Door Station Code DIP Main Connect Port SPK adjustment 1 2 3 4 ON DIP JP LK RS485 Connect Port 1 2 3 1 ...

Страница 3: ...power input connect to the power positive power S1 S2 Lock power output to connect 2 locks S Lock power output connect to the power input of locks only when using the camera to power the locks if using the external power supply for the locks the S will not be connected 3 Door Station Mounting adjust camera angle 1 2 4 3 Drill holes in the wall to match the size of screws and attach the rainy cover...

Страница 4: ...ttach the panel to the mounting box and use screws supplied to fix the panel Place name label Connect the cable correctly and adjust right angle for camera adjust camera angle PS Adjusting Camera Angle use a screwdriver to loosen the screw then adjust an appropriate camera angle after finishing use the screwdriver to fix the screw 3 ...

Страница 5: ... plastic cover on right left side to move away the cover insert a name paper then put the plastic cover back to the panel RF CARD 4 System Wiring and Electric Lock Connection Basic Connection AC monitor PS4 L1 L2 PL S1 S2 S 4 D2A ...

Страница 6: ...ult Door Lock Controlled with Dry Contact Note 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to AC or DC 24V 3A 3 The jumper must be taken off before connecting 4 Setup the Unlock Mode of Monitor for different lock types Power on to unlock type Unlock Mode 0 by default Power off to unlock type Unlock Mode 1 EB LOCK BUS PL S1 S2 S LOCK 2nd 1...

Страница 7: ... 3 S W V17 11 418 00 Local addr Unlock timing Video standard UI CODE MCM VER Updated Home Installer setup Caliber TouchScreen Code Number 0010 Remove all remote control 0011 Add remote control 8000 Set as master unit 0 8001 Set as slaver unit 1 8002 Set as slaver unit 2 8003 Set as slaver unit 3 8004 Set as guard unit 8005 Set as not guard unit 8006 Panel on as slaver unit called 8007 Panel off as...

Страница 8: ...ction 85 260VAC D2A PS5 monitors L1 L2 PL S1 S2 S L1 L2 PL S1 S2 S L1 L2 PL S1 S2 S L1 L2 PL S1 S2 S 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 Camera ID 00 ID 10 ID 01 ID 11 2 Camera 3 Camera 4 Camera DBC4 A B C D BUS 7 D2A ...

Страница 9: ...N OUT Wiring Mode Multi Monitors Connection Code 0 DIP 6 off Code 14 DIP 6 off Code 15 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON monitor monitor monitor 1 2 3 4 ON ID 00 85 260AC D2A PS5 RF CARD 8 ...

Страница 10: ...t3 The relay 2 doesn t respond the second lock showing user cards controlled two locks or pressing unlock 2nd on monitor can not release the second lock During this time After continuously showing access card 10 times the relay 2 will be closed for 60 seconds the blue LED relay 2 will be illuminated for 60 seconds and the buzzer will continuously sound If the system is connected alarm the alarm fu...

Страница 11: ...y when you add or delete user cards Please keep it well for future use Bit state User Code Bit state User Code Bit state User Code Code 0 Code 6 Code 11 Code 1 Code 7 Code 12 Code 2 Code 8 Code 13 Code 3 Code 9 Code 14 Code 4 Code 10 Code 15 Code 5 Bit 1 to Bit 5 are used to User Code setting The DPC D244 responds to 0 15 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1...

Страница 12: ...w Show the MASTER CARD ADD card to ID card window again format operation is performing red red red on blink off off off off blue blue blue beep beep beep beep beep Show the MASTER CARD ADD card to ID card window in standby mode Press CALL button At the same time show user cards to be added one by one Show the MASTER CARD ADD card to exit But it will return to standby mode if no operation within 15...

Страница 13: ...ease the first lock red indicator lights up Note2 if the user card control two locks show the user card to ID card window in standby mode the red blue indicator blink for 1 5s alternately During this time press CALL button to release the second lock Otherwise release the first lock if there isn t any operation within 1 5 seconds If 10 times unauthorized access cards are continuously attempted the ...

Страница 14: ...please use a little pure water or dilute soap water to clean the dust The unit is weather resistant However do not spray high pressure water on access control keypad directly Excessive moisture may cause problems with the unit You must use the right adaptor which is supplied by the manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service...

Страница 15: ...tor quantity 20 Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 When Monitor quantity 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1 5 mm2 70 50 30 The farest monitor B A C PS5 DBC DBC 4 monitor monitor monitor with two or four monitors RF CARD Note If the monitor has been specified the distance refer to the parameter 14 D2A ...

Страница 16: ...The design and specifications can be modified without notice to the user Right to interpret and copyright of this manual are reserved ...

Отзывы: