background image

X

X

X

T

T

T

E

E

E

 

 

 

E

E

E

L

L

L

E

E

E

C

C

C

T

T

T

R

R

R

O

O

O

N

N

N

I

I

I

C

C

C

 

 

 

 
 

 

 User’s Manual 

 6 

 11

 

 

7. Front Panel: Controls and Indicators 

 

LEVEL

0

1

2

8

9

10

3

4

5

6

7

LEVEL

0

1

2

8

9

10

3

4

5

6

7

LEVEL

0

1

2

8

9

10

3

4

5

6

7

LEVEL

0

1

2

8

9

10

3

4

5

6

7

LEVEL

0

1

2

8

9

10

3

4

5

6

7

LEVEL

0

1

2

8

9

10

3

4

5

6

7

MASTER

0

1

2

8

9

10

3

4

5

6

7

POWER

NOISE GATE

INPUTS

ACTIVATION

GAIN

TREBLE

MIDDLE

BASS

GAIN

TREBLE

MIDDLE

BASS

GAIN

TREBLE

MIDDLE

BASS

GAIN

TREBLE

MIDDLE

BASS

GAIN

TREBLE

MIDDLE

BASS

GAIN

TREBLE

MIDDLE

BASS

CH1

ON

-15dB

-7dB

0dB

+3dB

CH2

CH3

CH4

CH5

CH6

OPEN

CLOSE

GATE

LEVEL METER

PROFESSIONAL

AMPLIFIED MIXER

EV

 

240

P

I

0

5

4

3

8

7

6

11

12

10

9

1 2

 

 

1. 

TREBLE – MICRO/LINE and AUX inputs Treble tone control 

2. 

GAIN – MICRO/LINE and AUX inputs gain control 

3. 

MIDDLE – MICRO/LINE and AUX inputs Middle tone control 

4. 

BASS – MICRO/LINE and AUX inputs Bass tone control 

5. 

LEVEL – MICRO/LINE and AUX inputs level control 

6. 

LEVEL METER – Output signal level led indicator 

7. 

ON – Power on led indicator 

8. 

MASTER – Main level control 

9. 

OPEN – Open inputs status led indicator 

10. 

CLOSE – Close inputs status led indicator 

11. 

GATE – Noise Gate activation threshold control 

12. 

POWER – Power on switch 

 

 

8. Back Panel: Controls and Connectors 

 

1

3

2

PUSH

1

3

2

PUSH

1

3

2

PUSH

1

3

2

PUSH

1

3

2

PUSH

1

3

2

PUSH

230 V~ 50÷60Hz

FUSE T               A/250V~

S.N.

MAINS

Made in Italy

PROTECTION DO
NOT REMOVE SCREW

GROUNDING

FOR CONTINUED

GND LIFT

PRE OUT

LINK IN

RETURN

SEND

EFFECT

REC

AUX 2

AUX 1

CH 6

CH 5

CH 4

CH 3

CH 2

CH 1

BALANCED MICRO/LINE INPUT

1Hz

6Hz

15Hz

SHIFT

PROCESS ON

BY-PASS

-10

0dB

FREQUENCY

OUTPUT

LEVEL

ANTILARSEN PROCESSOR CONTROLS

-

+

FIRE OR ELECTRIC SHOCK DO NOT EXPOSE

TO REDUCE THE RISK OF

THIS EQUIPMENT TO RAIN OR MOISTURE.
TO PREVENT THE RISK OF FIRE HAZARD

WARNING:

REPLACE WITH SAME TYPE 250 VOLT FUSE.

PRE OUT

GND

COLD -

HOT +

LINK IN

GND

HOT +

EFFECT

100V

70V

50V

COM

-

Ω

4

POWER OUTPUT

+

3 = COLD -

2 = HOT +

1 = GND

3

2

1

XLR BAL INPUT

CHANNEL

6 5 4 3 2 1

24V

PHANTOM

ON

13

14

15

16

17

18

19

20

21

22

24

25

27

26

26

23

 

 

13. 

POWER OUT – Output connector for loudspeaker lines connection (Only for EV120P and EV240P) 

14. 

BY-PASS – Feedback Suppressor exclusion switch 

15. 

PROCESS ON – Feedback Suppressor activation status led indicator 

16. 

OUTPUT LEVEL – Feedback Suppressor output signal level control 

17. 

- / + – Feedback Suppressor signal shift frequency sum or subtraction selector 

18. 

SHIFT FREQUENCY – Feedback Suppressor signal shift frequency control 

19. 

MAINS – AC 230V power supply socket, with incorporated protection fuse 

20. 

GND LIFT – Selector for the connection of the electric ground with chassis 

21. 

PRE OUT – Mixed balanced output of the amplifier “PRE” section 

22. 

LINK IN – Unbalanced input, mixed and main level control dependent 

23. 

EFFECT – Unbalanced In / out for external signal processor insertion 

24. 

REC – Mixed stereo line output 

25. 

AUX1 / AUX2 – Stereo line input 

26. 

MICRO / LINE – Balanced input with variable sensitivity 

27. 

PHANTOM 24V – 24V Phantom activation selector for 

CH1, CH2, CH3, CH4, CH5 and CH6 inputs

 

 

 

 

Содержание EV6P

Страница 1: ...vo o ol llu u ut t ti iio o on n n S S Se e er r ri iie e es s s P P Pl llu u us s s E E EV V V6 6 6P P P E E EV V V1 1 12 2 20 0 0P P P E E EV V V2 2 24 4 40 0 0P P P A A Am m mp p pl lli iif f fi i...

Страница 2: ...atures 5 7 Front Panel Controls and Indicators 6 8 Back Panel Controls and Connectors 6 9 Power Supply 7 10 Connections 7 10 1 General criteria 7 10 2 Balanced Mic Line Input 7 10 3 Pre Out 7 10 4 Mai...

Страница 3: ...used 12 Connect according to the instructions only 13 Do not connect input signal higher than that indicated in the manual 14 Do not connect the amplifier output to the input of another channel 15 Do...

Страница 4: ...ver s antenna Make sure that the unit concerned conforms to the EMC immunity limits CE labelled All electrical equipment sold in the EC should be approved as for what concerns protection against elect...

Страница 5: ...lines and constant voltage This evolved version of Evolution Series has been improved with Noise Gate and Feedback Suppressor processor to optimize the product performance also in very difficult noise...

Страница 6: ...OR CONTINUED GND LIFT PRE OUT LINK IN RETURN SEND EFFECT REC AUX 2 AUX 1 CH 6 CH 5 CH 4 CH 3 CH 2 CH 1 BALANCED MICRO LINE INPUT 1Hz 6Hz 15Hz SHIFT PROCESS ON BY PASS 10 0dB FREQUENCY OUTPUT LEVEL ANT...

Страница 7: ...necting a microphone it should pay attention to the model if dynamic or electret In case of dynamic microphone do not insert 24 Vdc insert it with electret microphone only CH5 and CH6 socket cannot be...

Страница 8: ...loudspeakers that has to be equal or lower than the RMS power value of used amplifier It s a good rule arranging a 10 20 safety margin on the amplifier power capability Constant impedance lines 4 Ohms...

Страница 9: ...thermal protection is of the self resetting type and is tripped when the equipment reaches an excessively high temperature This may be due for example to the fact that the ambient temperature is too h...

Страница 10: ...microphones are used Ensure that all the Gains and Volume controls are at minimum and that the Tone controls are flat Keep the master volume for each output channel at about 10 20 Keep the input chan...

Страница 11: ...1 4V 43 5dBu 5 5mV 1 4V 43 5 dBu 5 5mV 1 4V MICRO LINE Inputs Sensitivity 59 11dBu 0 8mV 218mV 59 11dBu 0 8mV 218mV 59 11dBu 0 8mV 218mV Micro balanced inputs Impedance 10 Kohm 10 Kohm 10 Kohm Bass c...

Отзывы: