![XTA DP6i Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/xta/dp6i/dp6i_operators-manual_3678927003.webp)
DP6i
Operators Manual
Page 3
00
DP6i
DP6i
DP6i
DP6i
Quick Reference
THINGS YOU NEED TO KNOW
The parameters and their values are listed in the table below.
Parameter
Values
Notes
ID NUMBER
00 - 32
Shadow ID’s only available when interface is set
to ‘slave’ (INTERFACE 06 - 08)
INTERFACE
00
Master RS232 38400 baud
01
Master RS485 38400 baud
02
Master RS232 19200 baud
03
Master RS485 19200 baud
04
Master RS232 9600 baud
05
Master RS485 9600 baud
06
Slave RS485 38400 baud
07
Slave RS485 19200 baud
08
Slave RS485 9600 baud
09
Master RS232 38400 baud & Wiser Wireless
MIDI
Of
MIDI Relay Off
01 - 16
MIDI Relay ON channel specific – only available
when Interface is set to ‘Master’ (00 - 05)
Al
Midi Relay ON omni on
AES
AA
Analogue in – Analogue out
Ad
Analogue in – Digital out
DA
Digital in – Analogue out
DD
Digital in – Digital out – if no AES interface is
fitted or interface is set to ‘Slave (06 – 08),
display will be fixed at AA
GPI
of
GPI OFF – if no GPI interface fitted, display will
be fixed at Off
on
GPI ON – works in ‘simple’ mode only
By default, the LED display shows the last recalled memory
number as long as the memory hasn’t been edited remotely – then
it will display .
The memories cannot be recalled using the quick access keys
unless the unit is in the default mode – i.e. no yellow parameter
LEDs are illuminated (with the exception of the ‘Shadow’ LED).
Initially there will be no memories stored in the unit, so the quick
memory recall buttons will not function.
The Mute Unit key will silence the entire unit, but the meters will
continue to function. The remote software is unaware of this mute
function – it is local control only.