5 Series
5 Series
5 Series
Operator’s Manual
Page 3
5 Series
5 Series
5 Series
5 Series
Quick Reference
Editing channels :
press channel’s
GAIN
key. First press accesses
that channel’s gain. To scroll through channel’s parameters, use the
BACK
and
NEXT
keys. Second press accesses last viewed parameter.
Third press will drop back to the default screen.
Accessing menus:
press the
MENU
key. Use the
BACK
and
NEXT
keys to select the sub-menu required, and enter the sub-menu using the
ENTER
key. This applies to all levels of menu.
ENTER
always
confirms selections.
The Menus and their Contents
GLOBAL MEMORY
GLOBAL MEMORY
GLOBAL MEMORY
GLOBAL MEMORY
Sub-menu: Recall/Store/Erase input, graphic
EQ, dynamic EQ, and crossover settings, or combinations of these.
INPUT SECTION
INPUT SECTION
INPUT SECTION
INPUT SECTION
Sub-menu: Set up input ganging, and GEQ ‘Q’
setting.
CROSSOVER
CROSSOVER
CROSSOVER
CROSSOVER
Sub-menu: Set up or adjust crossover design, including
routing and auto limiter setting. Also set up output ganging.
INTERFACE
INTERFACE
INTERFACE
INTERFACE
Sub-menu: Comms interface setup (RS232 and RS485),
G.P.I. interface configuration, and wireless interface.
SYSTEM
SYSTEM
SYSTEM
SYSTEM
Sub-menu: Used to view unit’s status, and select various
global options such as PEQ ‘Q’ or bandwidth units, delay units, and
output metering point (pre/post mute).
SECURITY
SECURITY
SECURITY
SECURITY
Sub-menu: Used for locking various operations of the
unit, using a 4 digit code.
AES/EBU
AES/EBU
AES/EBU
AES/EBU
Sub-menu: Switch outputs from analogue to digital and
monitor AES input status info. (AES inputs are switched via rear panel.)
DYNAMIC
DYNAMIC
DYNAMIC
DYNAMIC
Sub-menu: Change how gain reduction meters behave.
Notes
The output meters show level, in dB from the limiter threshold, and the
input meters show level from clipping the A-D converters,
pre-gain and all EQ.
When editing DEQ or compressors, meters read downwards and show
gain reduction for each DEQ section or compressor respectively.
The high and low pass crossover filters are defined independently on
each output channel.
To access the limiter attack and release parameters, select “AutoLimiter
TimeCst: No” when designing a crossover.
To swap parametric filter units between bandwidth (‘BandW’) and ‘Q’,
enter
System
System
System
System
Sub-menu, select ‘Filter Q / Bandwidth’, and select
required readout units.
To swap delay time units, enter
System
System
System
System
Sub-menu, select ‘Delay
Time / Distance’, and select required readout units.
Pressing an
EDIT
key flashes corresponding channels routed to / from
that channel.