25
maintenance intructions
CAUTION:
Only certified electrician can service the motor.
Contact the authorized dealer for service or additional information.
User Maintenance Instructions:
General Inspection:
Inspect the motor at regular intervals, approxi-
mately every 500 hours of operation or every 3 months, whichever occurs
first. Keep the motor clean and the ventilation openings clear. Check that
the motor is clean. Check that the interior and exterior of the motor is free
of dirt, oil, grease, water, etc. Oily vapor, paper pulp, textile lint, etc. Can
accumulate and block motor ventilation. If the motor is not properly venti-
lated, overheating can occurs and cause early motor failure.
Lubrication & Bearings:
Bearing grease will lose its lubrication ability
over time. The lubricating ability of grease (over time) depends primar-
ily on the type of grease, the size of the bearing, the speed at which the
bearing operates, and the severity of the operation conditions. Good re-
sults can be obtained if the following recommendations are used in your
maintenance program.
Type of Grease:
A high grade ball or roller bearing grease should be
used. Recommended grease for standard service conditions is Polyrex
EM (Mobil).
Equivalent and compatible grease include:
Texaco Polystar, Rykon Premium #2, Pennzoil Pen 2 Lube and Chevron
SRI-2.
- Maximum operating temperature for standard motors=110°C.
- Shut-down temperature in case of a malfunction = 115°C.
Lubrication Intervals:
Recommended lubrication intervals are every
2200hours. For more information contact the authorized service center.