STEP 7 - Test Installation
1. Plug electrical cord into a grounded 3-prong outlet.
2. Do not use an outlet controlled by an off/on wall switch. Turn thermostat control dial
clockwise to the highest position. Maximum temperature will be reached in about15 minutes
and dispenser will be ready for use. Lower the temperature setting by turning thermostat
control dial counter clockwise if you notice vapour or a boiling noise. To raise or lower the
water temperature, rotate the thermostat dial. At the LOW setting of thermostat dial water
temperature will be approximately 60(±5)
0
C and the HIGH setting of the thermostat dial water
temperature will be approximately93(±5)
0
C.
7.0 CLEANING AND MAINTENANCE
Seasonal Shutdown
To prevent damage or mineral build up water must be drained regularly.
1. Unplug dispenser tank to power supply.
2. Turn thermostat control dial to OFF position (fully counter clockwise).
3. Turn faucet on and run water until water is cold.
4. Place a 3 L container under the drain plug at bottom of the tank.
5. Use a screwdriver to remove the screw and O-ring in the drain tube opening. When tank is
fully drained replace O-ring and screw. Tighten to reseal the drain.
NOTE: Do not plug appliance into power supply if tank is empty
.
8.0 TROUBLESHOOTING
The following situations are not covered by the One Year Replacement Warranty.
1.0 Water is not hot: (assuming cold water supply is connected properly and valve is open).
•
Check if dispenser is plugged in.
•
Turn thermostat control dial fully clockwise. This may produce boiling water in approximately
15 minutes and possibly be accompanied by a gurgling sound in the tank and/or water
"sputtering" from the faucet.
•
If the water boils, turn thermostat control dial slightly counter clockwise until the gurgling
and/or "sputtering" stops. This should take place within 20 seconds. Turn control dial an
additional 3mm counter clockwise at the tip of the dial. Wait 15 minutes and check the
temperature of the water.
•
Check for blown fuse or circuit breaker is tripped (also see IMPORTANT NOTE explaining
the self re-setting thermal fuse in step 6 of installation).
NOTE: The thermostat activates the heater after water temperature in the tank drops approximately
8
o
C from the maximum setting. The dispenser does not produce a continuous flow of hot water.
2.0 Hot water drips or sputters from faucet: