background image

WARNING:  INADVERTENTLY CONNECTING THE UNIT TO HOT WATER WILL DESTROY THE MODULE AND VOID THE WARRANTY.  THE FEEDING 
WATER TEMPERATURE CANNOT EXCEED 40

O

 C. 

 
 
 

 

6.0 CONNECTING UP AX5-TW

 

Check the labeling detail on AX5-TW system before connecting up the system. 
 

1. Connect 

the 

WATER IN

 tubing to brass ball valve, which is attached to the ½” pipe adapter.  With the other end of the tubing, connect it to the pressure 

valve followed by the first stage of the AX5-TW system.  The first stage of the AX5-TW system is marked with “

IN

” from the left hand side of the system.   

2. 

Connect the outlet “

OUT

” from the AX5-TW to the sink top faucet. 

 
 

6.1 QUICK INSERT PUSH IN FITTING 

Tube connection has never been easier than with Xsential quick connect fittings.  
NOTE: 

Fittings and tube should be kept clean, bagged and undamaged before use. 

 

Step 1 - Prepare the connection:

 

Cut the tube square ensuring it is free of score marks.  We recommend the use of one of the tube cutter for a perfect cut.  For soft or thin walled plastic tube we 
recommend the use of a tube insert. 
 

 

Do NOT use a hacksaw

 

 

NOTE: 

To avoid damage to the 'O' Ring, make sure 

burrs and sharp edges are removed from the cut end of 

the tube. 

 

 

Do not insert fingers into the fitting as the 

stainless steel teeth may cause injury.

 

 
With the fitting clean and undamaged and the tube cut square, you are now ready to make the connection. 

 
Step 2 - Assemble the connection:

  

Push the tube into the fitting, until the tube stops. The collet (gripper) has stainless steel teeth which holds the tube 
firmly in position whilst the 'O' Ring provides a permanent leak proof seal. 
Pull on the tube to check it is secure.  It is good practice to test the system prior to leaving site and/or before use.  It is 
recommended (and good practice dictates) that you remember to pressure test the completed installation before use. 

 
Disconnecting standard push-in fittings:

 

 
Ensure system is depressurized before removing fittings.  Push the collet in against the tube (center of the fitting). With 
the collet held in this position the tube can be removed.  The fitting can then be re-used. 
 

 
7.0 START UP PROCEDURE

 

1. 

With everything connected, turn on the ball valve.  

2. 

Open faucet.  

3. 

Check for leaks. (If anything is leaking shut off water, repair, then start with step 1 again).  

4. 

Within a few seconds the water will start to run.  

5. 

Let the water run for 10 minutes. This flushes out any carbon fines. 

6. 

The system is now ready to be used. 

7. 

Check for leaks daily in the first week and periodically thereafter. 

 
 

8.0 OTHER WATER APPLIANCE PROTECTION RANGE OF XSENTIAL WATER FILTRATION 

There are many appliances that require water of good quality.   These appliances include combi-steamer ovens, coffee machines, ice makers, hot water urns, post 
mixers, dishwashers and other water feed appliances.  A good quality water filtration system will help; 
 

 

Reduce sediment, rust and sand particles 

 

Reduce unpleasant taste and odour  

 Prevent 

corrosion 

 Reduce 

chlorine 

 

Prevent scale build up 

 

    

    

   

 

 

Contact Xsential on

 1300 366 295

 or visit www.xsential.com.au for details of other products 

 
 

 

Xsential Pty Ltd

 

78 Daly Street Belmont Western Australia 6104 

Ph: 1300 366 295 

www.xsential.com.au 

 