WARNING: INADVERTENTLY CONNECTING THE UNIT TO HOT WATER WILL DESTROY THE MODULE AND VOID THE WARRANTY. THE FEEDING
WATER TEMPERATURE CANNOT EXCEED 40
O
C.
6.0 CONNECTING UP AX5-TW
Check the labeling detail on AX5-TW system before connecting up the system.
1. Connect
the
WATER IN
tubing to brass ball valve, which is attached to the ½” pipe adapter. With the other end of the tubing, connect it to the pressure
valve followed by the first stage of the AX5-TW system. The first stage of the AX5-TW system is marked with “
IN
” from the left hand side of the system.
2.
Connect the outlet “
OUT
” from the AX5-TW to the sink top faucet.
6.1 QUICK INSERT PUSH IN FITTING
Tube connection has never been easier than with Xsential quick connect fittings.
NOTE:
Fittings and tube should be kept clean, bagged and undamaged before use.
Step 1 - Prepare the connection:
Cut the tube square ensuring it is free of score marks. We recommend the use of one of the tube cutter for a perfect cut. For soft or thin walled plastic tube we
recommend the use of a tube insert.
Do NOT use a hacksaw
NOTE:
To avoid damage to the 'O' Ring, make sure
burrs and sharp edges are removed from the cut end of
the tube.
Do not insert fingers into the fitting as the
stainless steel teeth may cause injury.
With the fitting clean and undamaged and the tube cut square, you are now ready to make the connection.
Step 2 - Assemble the connection:
Push the tube into the fitting, until the tube stops. The collet (gripper) has stainless steel teeth which holds the tube
firmly in position whilst the 'O' Ring provides a permanent leak proof seal.
Pull on the tube to check it is secure. It is good practice to test the system prior to leaving site and/or before use. It is
recommended (and good practice dictates) that you remember to pressure test the completed installation before use.
Disconnecting standard push-in fittings:
Ensure system is depressurized before removing fittings. Push the collet in against the tube (center of the fitting). With
the collet held in this position the tube can be removed. The fitting can then be re-used.
7.0 START UP PROCEDURE
1.
With everything connected, turn on the ball valve.
2.
Open faucet.
3.
Check for leaks. (If anything is leaking shut off water, repair, then start with step 1 again).
4.
Within a few seconds the water will start to run.
5.
Let the water run for 10 minutes. This flushes out any carbon fines.
6.
The system is now ready to be used.
7.
Check for leaks daily in the first week and periodically thereafter.
8.0 OTHER WATER APPLIANCE PROTECTION RANGE OF XSENTIAL WATER FILTRATION
There are many appliances that require water of good quality. These appliances include combi-steamer ovens, coffee machines, ice makers, hot water urns, post
mixers, dishwashers and other water feed appliances. A good quality water filtration system will help;
•
Reduce sediment, rust and sand particles
•
Reduce unpleasant taste and odour
•
Prevent
corrosion
•
Reduce
chlorine
•
Prevent scale build up
Contact Xsential on
1300 366 295
or visit www.xsential.com.au for details of other products
Xsential Pty Ltd
78 Daly Street Belmont Western Australia 6104
Ph: 1300 366 295
www.xsential.com.au