background image

1

1) Do not expose the 

Intelli

SUPPLY to rain, snow, spray, or bilge water. To reduce risk of fire

hazard, do not cover or obstruct the ventilation openings. Do not install the charger in a

zero-clearance compartment. Overheating may result.

2) The 

Intelli

SUPPLY is designed to be permanently connected to your AC and DC electrical systems.

3) The 

Intelli

SUPPLY is designed to charge 12V, 14V and 16V lead-acid batteries of all types. 

Do not attempt to use with batteries of other voltages

4) Never use chargers at a location where there is danger of gas or dust explosions.

5)  Use only attachments recommended or sold by the manufacturer. Doing otherwise may result in

a risk of fire, electric shock, or injury to persons.

6)  Do not disassemble the 

Intelli

SUPPLY. Attempting to service the unit yourself may result in a risk of

electrical shock or fire. Internal capacitors remain charged after all power is disconnected.

7) Do not open the 

Intelli

SUPPLY. There are no user serviceable parts inside the unit. For  service see 

the Returns policy in the back of this guide.

8)  The charger must be provided with an equipment-grounding conductor connected to the AC input

ground.

9) To reduce the risk of electrical shock, disconnect both AC and DC power from the charger before

attempting any maintenance or cleaning or working on any circuits connected to the charger. Turning

off controls will not reduce this risk.

10)  Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged

in any way.

11) Be sure AC and DC cords are not pinched or otherwise damaged by hoods, doors, or other 

moving engine components.

12)  Never attempt to charge a frozen battery.

13)  

Fuse Holder:

  Contains a 10A fuse in case of overload.

14)  

AC Cord:

  Grounded 3-pin 110V cord for use with grounded outlets only.

15)  

Battery Clamps and Cord:

  Allow for connection to the battery.

important safety instructions

XS Power

 Intelli

SUPPLY 

User Guide

Chapter 1

General safety Precautions

    

WARNING:

  Before installing and using the charger, read all instructions and cautionary markings on 

the charger, the batteries, and all appropriate sections of this guide.

Содержание IntelliSUPPLY PSC15

Страница 1: ...MicroprocessorControlledMulti Stage12V 14V 16V AutomaticPowerSupplyandBatteryCharger P NPSC15 PSC30 PSC60 Sleek On Board Design Remote LCD Display Three Mode Operation XS Flex Output Leads 120V 230V...

Страница 2: ...RANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHE...

Страница 3: ...2 explains how to operate the IntelliSUPPLY correctly to charge a performance battery and use the power supply feature Chapter 3 Troubleshooting p 12 Chapter 3 will help you identify and correct the c...

Страница 4: ...ser serviceable parts inside the unit For service see the Returns policy in the back of this guide 8 The charger must be provided with an equipment grounding conductor connected to the AC input ground...

Страница 5: ...to overcharging thanothers Ifindoubtastowhichbatterysettingtouseforyourapplication contactthemanufacturerofthebattery beingcharged OvercharginganAGMorgel cellbatterywillcausepermanentdamage Power Sup...

Страница 6: ...n 6 Charging Status 7 Battery Temperature Sensor note1 8 Remote Power Switch note2 9 LCD Remote Control PSC60 Product Introduction Note 1 Battery Temp Sensor To detect the battery temp While charging...

Страница 7: ...battery Or internal damage will result 12V 14V 16V C R P Mode Selection C Charge Mode R Recovery Mode P Power Supply Mode 12V 14V 16V C R P Mode Selection C Charge Mode R Recovery Mode P Power Supply...

Страница 8: ...ng normal operation It is safest not to install electrical equipment in these areas The unit is intended for use in a dry location Do not allow water or other fluids to drip or splash on the charger D...

Страница 9: ...DXOW 21 2 0RGH battery volt charging current charging mode ON OFF switch battery capacity DXOW 21 2 0RGH fault indicator red lighting DXOW 21 2 0RGH fault indicator red lighting DXOW 21 2 0RGH fault...

Страница 10: ...ed from loads The IntelliCHARGER is in stage two when the charge rate is declining 2 Select the correct battery voltage 3 Connect the red positive clip of the charger cables to the positive terminal o...

Страница 11: ...0 RH Non Condensing 10 95 RH 5 113 F 15 45 C 22 149 F 30 65 C 8 4 x 5 6 x 2 85 in 4 2lbs 1 9kgs 15A 15A 12V 14 4V 13 56V 14V 16 8V 15 82V 16V 12V 14V 16V 12V 14V 16V 19 2V 18 08V 14 4V 13 56V 16 8V 15...

Страница 12: ...2 5kgs 30A 30A 12V 14 4V 13 56V 14V 16 8V 15 82V 16V 12V 14V 16V 12V 14V 16V 19 2V 18 08V 14 4V 13 56V 16 8V 15 82V 19 2V 18 08V 14 4V 14 4V 16 8V 14 4V 16 8V 19 2V 16 8V 19 2V 19 2V 14 4V 16 8V 19 2...

Страница 13: ...5kgs 60A 12V 50A 14V 50A 16V 60A 12V 50A 14V 50A 16V 12V 14 4V 13 56V 14V 16 8V 15 82V 16V 12V 14V 16V 12V 14V 16V 19 2V 18 08V 14 4V 13 56V 16 8V 15 82V 19 2V 18 08V 14 4V 14 4V 16 8V 14 4V 16 8V 19...

Страница 14: ...battery acid contacts skin clothing or eyes 6 Wear complete eye protection and clothing protection Avoid touching eyes while working near batteries 7 If battery acid contacts skin or clothing wash imm...

Страница 15: ...ot come on when the power switch is flipped ON Check fuse Check cord and input power Voltage LED will not illuminate for 12V 14V or 16V The battery is not connected The battery is below 2 0V Charge ra...

Страница 16: ...onnections 5 0 1 5 m AWG 16 DC Output Connections 6 0 1 8 m AWG 10 Electrical Specifications 12V 14V 16V Absorption Voltage 14 40 VDC 16 80 VDC 19 20 VDC Float Voltage at no Load 13 56 VDC 15 82 VDC 1...

Страница 17: ...ed During this stage the charge rate current on the ammeter should close to the charge rate selected on the front panel switch Absorption Equalize Charge During the second stage known as absorption ch...

Страница 18: ...tage and time to determine when the battery is at 100 charge Extra electrical loads on the system will give the charger false information and therefore will prevent the charger from properly completin...

Страница 19: ...play a role in the answer here Given they were all XS Power 16V AGM batteries with a size of 45Ah at 100 discharged you can charge up to four in parallel in ten hours Calculating External Battery Cha...