Before calling the factory, please read through the Troubleshooting Guide.
The Bottle Filler Is Not Priming
Your XF460 XpressFill Bottle Filler is equipped with a diaphragm pump. Over time, the valve
is is an easily
e indication that a valve kit has failed is that the pump
does not prime, but you hear the pump running.
If you are desperate to bottle, try to fi ll the Transfer Kit with your product to get some workload
the pump and order a new valve kit as soon as possible.
I Have Uneven Fill Levels
erence in your fi ll levels, an orifi ce in the machine might be partly
clogged. Run warm water with your cleaning solution several times through the machine. If that
does not solve the problem, please contact us to evaluate further actions.
One Or More Spouts Are Dripping
After not using the machine for a while, you might have a spout that keeps dripping after the
fi
e rubber parts in the check valve may be dry but will usually seal again after starting
and stopping the fl ow. Simply run your fi ll cycle a couple of times, preferably with water or your
cleaning solution. Please contact us to order new check valves if the problem persists.
4
Troubleshooting
Please note that the XF460/260 is a volumetric filler, not a level filler. You might encounter different
fill lines in your bottles due to differences in your bottles. Your bottle might have the same
weight, but have slight variances in wall thickness, neck size, punt, etc. This often translates to
slightly different fill heights.